Electrolux AEG BS8304021M Service Manual page 25

Table of Contents

Advertisement

Oven temperature sensor is fixed on one
F138
resitor value
Wrong configured cooking fan
F140
Water level sensor (NTC) in steamer out of
range.
This Fault appears in case the steam generator
is overheated because the water refilling to the
F142
system is prevented.
Humidity sensor out of range
F143
F191
Oven temperature sensor (PT500) out of range
(Warning)
Foodprobe tmeperature value too high
F192
Humidity sensor out of range warning
F193
Oven temperature sensor (PT500) out of range
F194
(Warning)
F195
Electronic temperature value too high
Electronic temperature value out of range
F196
(warning)
Water level sensor (NTC) in steamer out of
range.
F197
Programming not correct
F203
F208
Configuration does not match to firmware of
F214
user interface
Unexpected content of configuration
F215
F233
F239
No communication between user interface and
Technical Support - BSP
Check Powerboard
Check temperature sensor
Check software version and compare
with sparepart software
Check the Tubes are clogged
Check the Tubes assembly
Check the Descaling actuator is closed
Check the Inlet valve functioning
Check the Ambient temperature where
the appliance is placed ( it should not
be too low )
Check if sensor is powered on in
correct way
Check the Wiring
Check wiring
Check temperature sensor
Check powerboard
Check wiring
Check foodprobe sensor and/or food
probe connection box
Check Foodprobe module
Check if sensor is powered on in
correct way
Check the Wiring
Check wiring
Check temperature sensor
Check powerboard
Check Powerboard
Check Powerboard
Check the Tubes are clogged
Check the Tubes assembly
Check the Descaling actuator is closed
Check the Inlet valve functioning
Check the Ambient temperature where
the appliance is placed ( it should not
be too low )
Check software version and compare
the sparepart softwareCheck User
Interface
Check software version and compare
with sparepart software
Check software version and compare
with sparepart software
Contact quality department
Check User Interface
25/27