Applicator Interface IN Signals
The Applicator Interface supports 8 digital input ports with optocouplers. All in
signals are asserted by setting the pin LOW and de-asserted by setting the pin
HIGH.
IN Signals Specification
Signal
Vin [High]
Vin [Low]
Simplified schematic of a digital IN port
IN Signals Connector Configuration
Pin
Signal
10
StartPrint_K
40
StartPrint_A
26
Feed_A
11
Feed_K
41
Pause_A
27
Pause_K
12
Reprint_A
42
Reprint_K
28
AppErr1_A
13
APPErr1_K
43
AppErr2_A
29
APPErr2_K
14
AppErr3_A
44
APPErr3_K
8
Description
Input Voltage High
Input Voltage Low
GND
Description
Start print Anode Opto In Channel
Start print Cathode Opto In Channel
Feed Anode Opto In Channel
Feed Cathode Opto In Channel
Pause Anode Opto In Channel
Pause Cathode Opto In Channel
Reprint Anode Opto In Channel
Reprint Cathode Opto In Channel
Applicator Error 1 Anode Opto In Channel
Applicator Error 1 Cathode Opto In Channel
Applicator Error 2 Anode Opto In Channel
Applicator Error 2 Cathode Opto In Channel
Applicator Error 3 Anode Opto In Channel
Applicator Error 3 Cathode Opto In Channel
Min.
Typical
10V
24V
-1V
0V
Applicator Interface Kit Installation Guide
Max.
40V
1V
INA