Inbetriebnahme
• Check if the operating data correspond to the values stated on the
rating plate.
• Do not modify the signal converter in any way whatsoever.
• Snap the mounting device of the signal converter onto a DIN rail.
• Connect the auxiliary power to terminals -X2/1(DC :L+ / AC: L) and
X2/2 (DC: L - / AC: N).
• Connect the FO cable assemblies with BFOC ST-connectors to
receiver R1 and transmitter T1 on the 1300 nm side and the FO
cable assemblies with FSMA screw-type connectors to receiver R2
and transmitter T2 on the 820 nm side.
• The signal converter is now operational as soon as the auxiliary
power supply is energized. The green LED lights to indicate that the
unit is operational.
Page 26 of 32
Repeater 820nm / 1300nm
s
1.7

Settings

All settings on the signal converter can be made from outside by means
of a DIL switch. It is not necessary to open the housing.
The settings are described in Section 1.4.2
1.8

Maintenance

The signal converter is maintenance-free.
Do not use liquids for cleaning the unit.
A 12/03
A 12/03
Repeater 820nm / 1300nm