CO Line Specifications

IP5122-SDC and CO-Line
Connection
CO
PSTN
Analog, Loop-Start
CO Line Circuit
Solid state secondary
protector, must meet
UL 497A
LAN
IPedge
Figure 1-6 IP5122-SDC Connectors
CO Line Specifications
1-18
The IP5122-SDC connects to the LAN via an IP Network (LAN, internet,
etc.) and is programmed the same as a IP5122-SDC in the IPedge
database. There is an additional connection for the CO-Line.
Connect the CO line via an RJ-11 to the IP5122-SDC. Refer to
Important!
The IP5122-SDC must have power, supplied by PoE or
local AC Adapter to function in ACO mode.
CAUTION! Solid state secondary protectors that meet UL 497A must
be installed on the analog CO line connected to IP5122-
SDC stations. The protectors must be properly
connected to an earth ground.
WARNING! Avoid using an IP5122-SDC connected to a CO Line
during a thunderstorm. There is a slight chance of
electric shock from lightning. Toshiba recommends
disconnecting the CO Line cord from the IP5122-SDC
when lighting is forecast.
Earth
ground
Note:
The IP5122-SDC must be powered by PoE or
local AC adapter for the CO Line to function.
The CO Line accessed by the ACO key has the following characteristics:

IP5122-SDC and CO-Line Connection

IPT Installation Manual Feb,, 2015