  • ENGLISH, page 7
3. Press the power switch () to switch on the char-
ging station
"
The power LED indicator on the front of the charging
station lights up green.
"
The charge indicator of the corresponding battery slot
lights up.
i
When charging is in progress the bars of the char-
ge indicator flash to indicate the charging status.
Each bar corresponds to 20% charge. Once all bars
light up without flashing, the storage battery is fully
charged.
4.2
Taking out the storage battery
1. Once the storage battery is fully charged, pull it out
of the slot from above.
2. Switch off the charging station
3. Unplug the charging station.
5.
Decommissioning
5.1
Change of location
If the 1 687 335 046 is passed on, all the documenta-
tion included in the scope of delivery must be handed
over together with the unit.
The 1 687 335 046 is only ever to be transported in
the original or equivalent packaging.
Unplug the electrical connection.
Heed the notes on initial commissioning.
5.2
Disposal and scrapping
1. Disconnect the 1 687 335 046 from the mains and
detach the power cord.
2. Dismantle the 1 687 335 046 and sort out and dis-
pose of the different materials in accordance with
the applicable regulations.
The 1 687 335 046 is subject to the Euro-
pean directive 2002/96/EC (WEEE).
Dispose of used electrical and electronic
devices, including cables, accessories and
batteries, separately from household waste.
Make use of the local return and collection
systems for disposal.
Proper disposal of 1 687 335 046 prevents
environmental pollution and possible
health hazards.
Robert Bosch GmbH
Operation | 1 687 335 046 | 9
6.

Technical Data

6.1
Temperature and humidity
Designation
Operating Temperature
6.2
1 687 335 046
Characteristic
Number of slots
Number of LEDs
Charging duration (at 25 °C)
6.3
Power supply unit
Characteristic
Input voltage (AC)
Output voltage (DC)
Output current
en
Value/range
5 °C – 40 °C
41 °F – 104 °F
Value/range
2
5 per slot
Maximum 5 hours
Value/range
100 V ~ 240 V
13.05 V
2.4 A (max.)
|
1 689 989 228