1 - Physical Installation

The XMS-1208P can easily be installed in a standard 19" rack. Two mounting ears are included for installing and stabilizing
the switch. When attaching the mounting ears and installing the switch in a rack, please refer to the following illustration:
Use the included screws to attach the mounting ears to each side of the switch.
Be sure the switch is level and properly secured in the rack.

Desktop Setup

For use as a desktop device, position and apply the included rubber feet to the bottom of the XMS-1208P.
2 - Connecting
Ethernet and Power Connections
Use one of the ten Ethernet ports to connect the XMS-1208P to any Ethernet-enabled device, including servers, routers,
or other switches. No crossover cable is necessary.
The XMS-1208P supports 10/100/1000 Mbps Ethernet; 10/100 Mbps half/full-duplex mode and 1000 Mbps full-
duplex mode. Ports 1-8 are PoE+ and are enabled by default. Ports 9 and 10 are Gigabit Ethernet only (non PoE), while
ports 11 and 12 are Gigabit SFP ports.
Use the included power cable to connect the XMS-1208P to a surge-protected outlet. The AC input socket is on the
rear panel. The built-in power supply supports 100~240Vac at 50-60Hz.

Network Cabling

If you plan to use a fiber optic link for the network connection, an optical fiber module is required (not included).
CAUTION: Multiple Uplink channels can create loops, resulting in network failure. Ensure only
one Uplink channel exists between switches or between the XMS-1208P and a router.
NOTE: When powering up, the port LEDs may take a moment to initialize. This is normal as the
XMS-1208P initialization and startup sequence completes.
NOTE: The XMS-1208P has an internal 130W power supply. Do not exceed 25.5W each or 130W
combined consumption of all external PoE devices.