Mounting and Connection Instructions Reader series "luminAXS"
10 3
.

General data

Interface range:
-
RS 485
-
-
Clock/Data
Connecting cable
-
RS 485
-
-
Clock/Data
Mounting surface
Protection category as per
Environmental class as per VdS
Environmental class as per
Operating temperature range
Storage temperature range
Relative humidity
Weight
D
imensions (W x H x D)
-
Reader
-
Mounting plate
-
Plastic housing (weather/view) (027965)
-
VdS Plastic housing (weather/view) (027965.10)
Colour
Hereby, the Novar GmbH declares that the radio equipment
Reader luminAXS Item no. 027913.10, 027914.10, 027915.10, 027910 to 027915 and
027922 to 027924 is in compliance with Directive 2014/53/EU.
The full text of the EU declaration can be downloaded from our homepage
https://www.security.honeywell.de/ in the service/download area.
11.

Cleaning and care

Housing and keypad:
The housing and keypad can be cleaned when necessary with a soft cloth.
Use a cloth moistened by water if heavily soiled.
Do not use cleaning agents, abrasives or solvents such as spirits, alcohol or petrol!
EN 60529
EN 50131-1
:
up to 2000 m
up to 200 m
shielded, length 4 m
5-core
8-core
Any surface, also metal
IP 65
III
I
II
-
25
°C to +
70
°C
-
30
°C to +
80
°C
93% non-condensing
150 g
80,4 x 80,4 x 13,5 mm
80,4 x 80,4 x 6,0 mm
95,0 x 89,2 x 50,0 mm
95,9 x 89,6 x 62,0 mm
graphite grey (similar to RAL 7024)