Mounting and Connection Instructions Reader series "luminAXS"
5.2
Mounting for f.m. wiring
Swiss boxes
f.m. socket (DIN)
(preferred installation)
60
Screw the reader base onto a standard flush mounted socket (DIN) or directly onto the wall. For sockets
from Switzerland, the reader is fixed at the corners.
Screw the backtamper onto the wall. If the reader breaks away, the bolt remains secured to the wall, the
cover contact to the reader is no longer actuated and is released.
5.3
Mounting for s.m. wiring
T h e d i s t a n c e p l a t e f o r w a l l
mounting (Item no. 027964) is
placed between the reader base
and the wall and securely screws
these to each other.
Following this, secure the back-
tamper.
The mounting plate can be rotated
in 90° steps so that the surface
mounted cable entry can be from at
the bottom, at the top, on the left or
right.
For mounting in accordance with VdS / EN / SES, the reader base must be
secured with 4 screws.
Reader bottom
75,5
60,0
f.m. socket
Pin for actuating
the cover contact
Attachment for
the backtamper
Distance plate
80,38
s.m. cable entry
2,8
24,7
Distance plate