Checking The Room Temperature Setpoints; Temporary Changes To The Room Temperature Setpoint; Manual Temperature Setpoint; Extension Of The Heating Program - Honeywell HM 80 Installation And Operation Manual

Universal mixing valve controller
Table of Contents

Advertisement

Available languages

Available languages

4.6.
Checking the room temperature
setpoints
The current room temperature is displayed during normal
operation.
In order to check the temperature, press the button .
The programmed temperature with the two small arrows
is displayed.
4.7.
Temporary changes to the room
temperature setpoint
Move the slide switch to the position
Set the temperature to the desired value using the buttons
or
.
TEMP
TEMP
The temperature returns to the programmed value at the
next room temperature setpoint.
4.8.

Manual temperature setpoint

Move the slide switch to the position
Set the manual temperature to the desired value using the
buttons
or
TEMP
TEMP
The value is adjusted faster if the button is kept
pressed. The temperature can be set in steps of
0.5 °C from 5 °C to 30 °C.
The manual temperature remains valid until the slide switch
is reset to the position
AUTO
4.9.

Extension of the heating program

Move the slide switch to the position
Press the button
Party.
Set the party time (1 to 23 hours) with the buttons
-.
Set the party temperature (5 °C to 30 °C) with the buttons
or
.
TEMP
TEMP
The CM67RFMV regulates the set temperature for the
set period and then returns to the normal program.
Press the button
Party
order to interrupt the party setting

4.10. Activating the Sunday program

4.10.1.
Activating the Sunday program for
the following day
Move the slide switch to the position
Press the button
(
DAY OFF
A
symbol is displayed and the day marking for the
following day flashes. This indicates that the Sunday
program will be used on the following day. On the
following day the
symbol is still displayed, however
without a flashing day marking. The Sunday program is
used.
.
AUTO
.
MAN
.
.
.
AUTO
+ or
again or move the slide switch in
.
.
AUTO
).
In order to delete the
DAY OFF
day, press the button
4.10.2.
Activating the Sunday program for
the current day
Press the button
(
DAY OFF
In order to delete the
DAY OFF
once more or move the slide switch.

4.11. Holiday program

Move the slide switch to the position that you want to have
when you return (
or
AUTO
Press the button
(
HOLIDAY
holiday counter and the temperature.
Set the holiday duration (1 to 99 days) with the buttons
+ or
-.
An additional flashing day marking shows the day of
return.
Set the holiday temperature (5 °C to 30 °C) with the
buttons
or
TEMP
TEMP
The CM67RFMV regulates the new temperature for the
set period. The holiday counter is reduced by 1 at each
midnight until the set number of days has passed. The
CM67RFMV then returns to the normal regulation
, depending on the setting of the slide switch.
AUTO
In order to delete the HOLIDAY setting, press the button
once more or move the slide switch.

4.12. Switching off the heating system

Move the slide switch to the position
In this operating mode the CM67RFMV activates the lower
temperature limit of 5 °C. This ensures that the heating pipe
work do not freeze up when it becomes colder.

4.13. Changing batteries

The CM67RFMV has an electronic monitoring function for
the battery charge state (durability of the battery without
other connected accessories approx. 2 years).
If the battery has to be displaced, a flashing symbol is
displayed.
The CM67RFMV has a permanent memory in order to retain
the program settings. Renewed programming after the
battery has been replaced is not necessary.
However, the time has to be corrected if you need more
than a minute to replace the battery (see "Inserting
batteries", Page 26).
Operation CM67RFMV
function for the following
twice or move the slide switch.
) twice.
function, press the button
).
MAN
) in order to display the
.
MAN
.
OFF
or
23

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents