All Cressi-sub regulators are certified for use up to 50 m/55 yd. Besides, in order to guarantee the maximum safety, the devi- and some for use in cold water with temperatures < 10° C/50°F, ces must be serviced only by the producer or an authorized- having got through the strict test at 4°C/39°F (+0 -2) prescribed...
Direction for use regulators 1.1 - T10 – T10 S.C. balanced diaphragm first stage 1.1 - MC9 balanced diaphragm 1st stage - MC9 S.C. 1.2 - MC5 balanced diaphragm 1st stage 1.3 - AC2 in-line piston 1st stage...
Page 5
HP valve mechanism to simplify maintenance and disassembling of the regulator. Thanks to this feature, the T10 first stage assists the diver in the It provides outstanding respiratory performance, constant in any dive, guaranteeing the highest working performance which in-...
Page 6
WARNING: intermediate pressure regulation should only be carried out by authorised Cressi-sub centres and the calibration As with all regulators in the Cressi-sub range, the T10 first stage values CANNOT and MUST NOT be changed by the user, to offers the possibility of making certain manufacturing compo- avoid prejudicing the good working order of the regulator.
Page 7
Venturi effect in the “dive” position. If possible, keep the regulator in warm surroundings when not in use. The Seal Chamber is used to make the T10 balanced diaphragm fig. 2 first stage completely waterproof, avoiding water entry not only...
Page 8
The Cressi-Sub authorised centres can be indicated by retailers or, alternatively by Cressi Sub s.p.a. (email: info@cressi-sub.it). The T10 first stage therefore can be used in cold water (with a water temperature under 10 °C), since it complies with Directive 89/686/EEC dated 21/12/1989, checked and certified by the Test Authority No.
Page 9
The regulation system of intermediate pressure in MC9 balanced solutions taken by designing MC9 1st stage, making it one of the diaphragm first stage is the same as all other Cressi-sub first best performing small and light regulators on the market.
Page 10
NOT be modified by the user, in order not to affect the or in cold water at temperature lower than 10 °C/50 °F. All inner- good working of the regulator. Cressi-sub decline any responsibility for components of the regulators are in fact perfectly watertight.
Page 11
FIRST STAGES The Seal Chamber is composed of a metal cap containing a sili- Visit our web-site www.cressi.com, where you can find further in- con seal. The seal responds to any environmental pressure formation relating to your safety. change bending towards the inside and transmitting it to the 1.3 –...
Page 12
The regulation system of intermediate pressure in MC5 balan- at his own high risk. ced diaphragm first stage is the same as all other Cressi-sub first stages, allowing an easy and quick adjustment of intermediate The first stage can be connected to the tank valve with an inter-...
Page 13
Both international yoke and DIN (at 200 or 300 bar) (2900÷4350 psi) connection are fully interchangeable and are replaced with each other very quickly (only at authorized Cressi-sub centres). Its satin finish guarantees the regulator’ s best surface perfor- mance, while contributing to its outstanding strength and relia- bility.
Page 14
Direction for use regulators 1.5 - Performance...
1.5 - Performance 1°stadio a membrana bilanciata T10 e T10 S.C. Working pressure (INT connection) 0÷230 bar Working pressure (DIN connection) 0÷300 bar Calibration pressure (with 200 bar supply) 10 bar Air supply 4500 l/min (*) High pressure (HP) ports...
Page 16
1.5 - Performance AC2 in-line piston 1st stage Working pressure (INT connection) 0÷230 bar - (0÷3365 psi) Working pressure (DIN connection) 0÷300 bar - (0÷4350 psi) Calibration pressure (200 bar feeding) 10 bar - (145 psi) Air supply 2100 l/min (*) High pressure (HP) ports Low pressure (LP) ports (*) Values measured at LP port with second stage connected and tank pressure at 200 ➡150 bar (2900 ➡2175 psi)
Page 17
Direction for use regulators 2.1 - Master 2 stage 2.2 - Ellipse Balanced 2 stage 2.3 - Ellipse Balanced 2 stage / Disassembly and maintenance 2.4 - Ellipse second stages 2.5 - Ellipse, disassembly and maintenance 2.6 - XS Compact Pro / XS Compact 2 stage 2.7 - XS Compact, disassembly and servicing 2.8 - XS2 2...
SECOND STAGES 2.1. - Master 2nd stage crosses it longitudinally where the air flows reaches the 1st stage, up to reaching a small chamber (called “balancing chamber”) placed on the end of the piston. The air contained in this chamber exerts a force that varies de- pending on the depth, that tends to push the closing piston to- wards the valve nozzle.
Page 19
SECOND STAGES the piston spring. Basically, screwing in the knob (clockwise direc- working that is placed on the mouthpiece, which in fact limits the tion) increases inhalation resistance, while unscrewing (anti-clock- Venturi effect, preventing the 2nd stage free flow. In the “DIVE” wise direction) decreases inhalation resistance.
Page 20
2nd stage performance. deal with diving in cold water (temperature <10°C or < 50°F ). Cressi-sub recommends you carry out this type of diving after The Cressi-sub Master second stage complies with Directive taking a specific course given by qualified instructors. Use of...
Cressi-sub. The Cressi-Sub authorised centres can be indicated by retailers or alternatively by Cressi Sub s.p.a. (email: info@cressi-sub.it). Using the Allen key provided with the regulator to unscrew the first stage HP and LP plugs, you can open and disassembly the 2nd stage case, directly accessing its internal mechanics.
SECOND STAGES 2.3 – Ellipse Balanced 2nd stage fig. 5 fig. 6 Ellipse balanced second stage is a revolutionary air balanced Second stage Ellipse Balanced is supplied with an air balanced regulator: it features an elliptical shape, small weight (only 170 g piston, showing a small diameter perforation all through its - the lightest in its class!) and state-of-the-art design, besides length.
Page 23
SECOND STAGES Ellipse balanced second stage is an adjustable regulator, that is it works at its best, increasing the air flow supplied to the regulator is possible to regulate the breathing effort. Operating an external to the maximum level. knob, it is possible to adjust the breathing effort varying the load of the piston spring.
WARNING: In case of dives in cold water (temperature vides the requisites of III class Individual Safety Devices: the device less than 10°C/50° F), Cressi-sub recommend to use a tank therefore is EC branded and reports the certifying institute indi- supplied with a valve featuring two separate outlet ports, with cation (0474), as prescribed by Art.
Visit our web-site www.cressi.it, where you can find further infor- sized regulators’. mation relating to your equipment.
Page 26
SECOND STAGES When touched, the lever opens the air supply valve, which has To optimize the Venturi effect, Ellipse is supplied with a new been completely redesigned. The air flowing out of the valve ergonomic flow deflector with two operating modes, clearly adjustable nozzle when the mechanism is open is led into the shown by the scale on the regulator housing: injector leading it directly to the mouthpiece.
Using the included Allen key to unscrew the HP and LP caps of Ellipse Cressi-sub is a downstream regulator, that is the valve the first stage, you can open and disassemble the second stage, automatically opens in case of calibration loss of first stage or of directly getting to its inner mechanism.
“downstream” regulators that are lightweight (just 135 gr - the lightest in the Cressi-sub line), with incredibly sleek design. Designed with meticulous attention to materials, they offer many new characteristics covered by numerous patents, and are man- ufactured in two specific versions: XS Compact PRO and XS Compact.
Page 29
Here, the air is accelerated by the vious regulators in the Cressi-sub line. It also has a special Venturi effect, causing a vacuum inside the case. In order to pre-...
Page 30
This means that any condition of over pressure upstream the second stage leads to automatic free flow, never causing the reg- ulator to get stuck. The range of Cressi-sub XS Compact regulators is compliant with fig. 14 directive 89/686/EEC of 21/12/1989, and has been tested and...
SECOND STAGES 2.9 – XS2 2nd stage The adjustable nozzle is placed inside the valve seat. The outflow air, when the mechanism is open, is directed through the injec- Second stage supplies air “on demand”, that is only when the tor and directly into the mouthpiece.
Page 33
The 2nd stage is connected to one of the first stage’ s 3/8” ports by means of a flexible medium pressure and high capacity hose. All Cressi-sub second stages are downstream, that is the valve automatically opens in case of calibration loss of first stage or of a sudden intermediate pressure increase.
Page 34
Direction for use regulators 2.10 - Performance...
2.10 - Performance Master 2nd stage Working pressure 0÷230 bar (INT); 0÷300 bar (DIN) Calibration pressure (with 200 bar supply) 10 bar (T10 - T10 S.C.) Average inhalation effort (*) 3 mbar Average exhalation effort (*) 7 mbar Average work of breathing (*)
Page 36
2.10 - Performance Ellipse black 2nd stage Working pressure INT: 0÷230 bar - (0÷3365 psi); DIN: 0÷300 bar (0÷4350 psi) Calibration pressure (200 bar feeding) 10 bar (MC5) - (145 psi) Average inhalation effort (*) 5,5 mbar Average exhalation effort (*) 11 mbar Average breathing effort (*) 1,1 J/l...
3.2 – Checks before use second stage as well. Before using your Cressi-sub regulator, we recommend to carry out some easy though very important and unavoidable checks, A last acoustic test might discover and/or point out possible los- in order to avoid any kind of problem.
We without tighten too much. recommend to use only original Cressi-sub spare parts. In case a second independent regulator is used, connect it to For yoke connected first stages, use following procedure: the additional valve outlet following the above instructions.
If your regulator is certified to be used in cold water (tempera- equipment may not be used at depths of greater than 30 me- tures < 10° C/50°F), Cressi sub recommend to follow carefully the ters, or at water temperatures below 10 °C.
Interventions carried out by untrained personnel may cause clubs etc), we recommend to disinfect it by placing it for 2/3 high risks to the diver’ s health and life. Cressi-sub decline any minutes in a 2% Stereamine G water solution or other similar responsibility for any servicing or setting of the regulators car- pharmaceutical products.
Page 42
All Cressi-sub regulators are supplied with NBR O-rings and all inner components are greased with silicone, that guarantee the best lubrication and protection from salted and corrosive sea environment. As proved by tests carried out by NASA (NASA DOCUMENT TR-900-001), using silicone lubricants is excellent for equipment using Nitrox hyper-oxygenated mixtures with oxygen percenta- ge up to 40%.
Page 43
DEALER MODEL SERIAL DATE TECHNICIAN'S NOTES ON PROCEDURES SIGNATURE (Date of the next NAME NUMBER NAME scheduled maintenance)
3.8 - Cressi-sub Certified Combinations. NOTE: Cressi-sub regulators can be used with SCUBA component units according to the certified combina- tions that comply with directive 89/686/EEC, and with standard EN 250:2014. FIRST STAGES MC9 S.C. T10 S.C. DIN/INT DIN/INT DIN/INT...
Page 45
Regulators Chart Primi Stadi First Stages Premiers Etages Erste Stufen Primeras Etapas ВТОРЫЕ СТУПЕНИ...