06 Protection Parameters

Pr.
Parameter Name
06-00
Low voltage level
06-01
Over-voltage stall prevention
Selection for over-voltage stall
 06-02
prevention
Over-current stall prevention
06-03
during acceleration
Over-current stall prevention
06-04
during operation
Acceleration / deceleration time
06-05
selection for stall prevention at
constant speed
Chapter 11 Summary of Parameter SettingsCP2000
Setting Range
230V: Frame A–D: 150.0–220.0 V
Frame E and above : 190.0–220.0 V
460V: Frame A–D: 300.0–440.0 V
Frame E and above : 380.0–440.0 V
575V: 420.0–520.0 V
DC
690V: 450.0–660.0 V
DC
0: Disabled
230V: 0.0–450.0 V
DC
460V: 0.0–900.0 V
DC
575V: 0.0–1116.0 V
DC
690V: 0.0–1318.0 V
DC
0: Traditional over-voltage and traditional over-current
stall prevention
1: Smart over-voltage and traditional over-current stall
prevention
2: Traditional over-voltage and smart over-current stall
prevention
3: Smart over-voltage and smart over-current stall
prevention
230V / 460V models
Light load: 0–130% (100% corresponds to the rated
current of the drive )
Normal load: 0–160% (100% corresponds to the rated
current of the drive)
575V / 690V models
Light load: 0–125% (100% corresponds to the rated
current of the drive)
Normal load: 0–150% (100% corresponds to the rated
current of the drive)
230V / 460V models
Light load: 0–130% (100% corresponds to the rated
current of the drive )
Normal load: 0–160% (100% corresponds to the rated
current of the drive)
575V / 690V models
Light load: 0–125% (100% corresponds to the rated
current of the drive)
Normal load: 0–150% (100% corresponds to the rated
current of the drive)
0: By current acceleration / deceleration time
st
1: By the 1
acceleration / deceleration time
nd
2: By the 2
acceleration / deceleration time
rd
3: By the 3
acceleration / deceleration time
th
4: By the 4
acceleration / deceleration time
5: By auto acceleration / deceleration
11-23
DC
DC
DC
DC
Default
180.0
200.0
360.0
400.0
470.0
480.0
380.0
760.0
920.0
1087.0
0
120
120
120
120
120
120
120
120
0