5.5.4 QUARTER TURN VALVE
WARNING
The quarter turn valve incorporates a bail style handle to allow opening/closing from either side. The valve locks in the off position to
prevent accidental opening. The valve also includes an internal mechanism that prevents the force of the water from influencing the
valve position. See LIA-355 2.5" Quarter Turn Hydrant Valve Manual for more information.
6.0 FLOW CHARACTERISTICS
The Hemisphere Transportable Monitor is designed for maximum flows of 500 gpm (2000 l/min) and a maximum pressure at the
nozzle, while flowing, of 175 psi (12 bar). Do not exceed these limits.
DANGER
6.1 HEMISPHERE PRESSURE LOSS
6.2 AUTOMATIC, FIXED, AND SELECTABLE FLOW NOZZLES
A variety of water or foam nozzles may be used with the Hemisphere. Automatic nozzles maintain a constant pressure by adjusting
their opening to match the available flow. Consult the nozzle manufacturer for maximum flow and pressure ratings. In all cases do
not exceed 500 gpm (2000 l/min) and/or 175 psi (12 bar) nozzle exit pressure.
6.3 STACKED TIPS AND SMOOTH BORE NOZZLES
NOZZLE
DIAMETER
FLOW
(GPM)
1.0 INCH
1-1/4 INCH
1-1/2 INCH
NOZZLE
DIAMETER
FLOW
(L/min)
25 MM
32 MM
1300
38 MM
1900
©Copyright Task Force Tips LLC 2013-2020
Sudden changes in valve position can cause pressure spikes (water hammer) and could lead to
hose failure or an out of control monitor. Open and close the valve slowly to avoid water hammer.
An inadequate supply of pressure and/or flow will cause an ineffective stream and can result
in injury or death. Choose operating conditions to deliver adequate fire suppression. See flow
graphs.
0
400
40.0
35.0
30.0
25.0
20.0
15.0
10.0
5.0
0.0
0
100
Pressure Loss for the Hemisphere Monitor
50 PSI
80 PSI
REACTION
FLOW
REACTION
(LBS)
(GPM)
210
80
266
328
120
415
473
177
—
4 BAR
6 BAR
REACTION
FLOW
REACTION
(KG)
(L/min)
830
40
1000
70
1700
90
—
FLOW EXCEEDS RATING OF HEMISPHERE TRANSPORTABLE MONITOR
FLOW (LPM)
800
1200
1600
200
300
400
FLOW (GPM)
Figure 6.1
NOZZLE EXIT PRESSURE
100 PSI
FLOW
REACTION
(LBS)
(GPM)
(LBS)
126
297
157
196
464
245
—
—
—
NOZZLE EXIT PRESSURE
8 BAR
FLOW
REACTION
(KG)
(L/min)
(KG)
60
1200
80
100
1900
130
—
—
—
24
2000
2.5
2
1.5
1
0.5
0
500
150 PSI
175 PSI
FLOW
REACTION
FLOW
REACTION
(GPM)
(LBS)
(GPM)
364
236
390
—
—
—
—
—
—
10 BAR
12 BAR
FLOW
REACTION
FLOW
REACTION
(L/min)
(KG)
(L/min)
1300
100
1400
—
—
—
—
—
—
(LBS)
275
—
—
(KG)
120
—
—
LIX-740 July 21, 2020 Rev08
Need help?
Do you have a question about the HEMISPHERE and is the answer not in the manual?
Questions and answers