Table of Contents

Advertisement

Available languages

Available languages

Quick Links

RMW8
Wireless System

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RMW8 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PROEL RMW8 Series

  • Page 1 RMW8 Wireless System...
  • Page 2: Table Of Contents

    RMW8 INDICE Precauzioni d’uso ..............................3 Descrizione ................................6 Funzioni E Controlli .............................. 6 Pannello Frontale............................... 6 Pannello Posteriore ............................7 Trasmettitore a Mano............................7 Trasmettitore Bodypack............................. 8 Operazioni................................9 Ricevitore RMW8............................... 9 Trasmettitore WHL / WML ..........................9 Installazione................................. 10 Tabella Frequenze (798.000-827.000mhz)......................
  • Page 3: Precauzioni D'uso

    RMW8 1. Precauzioni d’uso AVVERTENZA: Per ridurre il rischio di folgorazione, non rimuovere il coperchio (o il pannello posteriore). All’interno non sono contenute parti riparabili dall’utente; affidare la riparazione a personale qualificato. ATTENZIONE: Per ridurre il rischio d’incendio o di folgorazione, non esporre questo apparecchio alla pioggia o all’umidità. Questo simbolo, ove compare, segnala la presenza di un voltaggio pericoloso non isolato all’interno del corpo dell’apparecchio, voltaggio sufficiente a costituire un rischio di folgorazione.
  • Page 4 RMW8 Protezione del cavo di alimentazione Il cavo di alimentazione elettrica deve essere installato in modo che non venga calpestato o pizzicato da oggetti posti sopra o contro, prestando particolare attenzione a cavi e spine, prese a muro. Pulizia  Quando l’unità...
  • Page 5 In caso si verifichino interferenze nel circuito di provenienza, il valore di THD sarà superiore al 10%. Non installare questo apparato in una libreria o in altri luoghi a spazio ristretto.  PROEL S.p.A. declina ogni responsabilità in caso di scorretta installazione dell’unità.
  • Page 6: Descrizione

    RMW8 Grazie per aver scelto un prodotto PROEL e della fiducia riposta nel nostro marchio, sinonimo di professionalità, accuratezza, elevata qualità ed affidabilità. Tutti i nostri prodotti sono conformi alle normative CE per utilizzazione continua in impianti di diffusione sonora.
  • Page 7: B) Pannello Posteriore

    RMW8 b) Pannello Posteriore 1. UP / DOWN Selezione manuale delle frequenze pre-selezionate da 0 a 99 tramite la pressione sui tasti UP e DOWN. 2. Menu Tenendo premuto il pulsante per 1,5 secondi, si attiva la funzione Sq (vedi la sezione squelch Control) 3.
  • Page 8: D) Trasmettitore Bodypack

    RMW8 d) Trasmettitore Bodypack 1. Display Il display LCD mostra: simbolo d’antenna (se TX e RX sono agganciati), frequenza di lavoro, livello di carica della batteria, CANALE, potenza di trasmissione (PL), LOCK. 2. CH/ON Premendo per un secondo questo tasto il trasmettitore si accende, alle successive pressioni si passa ciclicamente alle seguenti funzioni: CHANNEL / PL / LOCK.
  • Page 9: Operazioni

    RMW8 4. Operazioni a) Ricevitore RMW8 Squelch Control Entrare nella modalità SQUELCH premendo il tasto MENU, il display mostrerà un numero tra 0 e 10 che indica il valore corrente della soglia come riportato dalla tabella: Numero Soglia di Squelch 95,0 dB 91,7 dB 88,3 dB...
  • Page 10: Installazione

    RMW8 Funzione Lock Entrare nella modalità Look/unlock premendo quattro volte il tasto CH/ON, il display mostrerà Look o unlock a seconda di quale è settato correntemente, mediante il tasto SELECT selezionare o deselezionare il blocco. Dopo alcuni secondi dall’ultima digitazione il display si riporta sulla schermata iniziale.
  • Page 11: Tabella Frequenze (798.000-827.000Mhz)

    RMW8 6. Tabella Frequenze (638.000-658.000mhz) CH 0 CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 9 CH 10 CH 11 638.125 638.325 638.525 638.725 638.925 639.125 639.325 639.525 639.725 639.925 640.125 640.325 CH 12 CH 13 CH 14 CH 15...
  • Page 12 Informazioni sulla conformità alla direttiva R&TTE Con la presente Proel S.p.A. dichiara che questo sistema radiomicrofonico è conforme ai requisiti essenziali ed alle altre disposizioni pertinenti stabilite dalla direttiva 1995/5 / CE. La dichiarazione di conformità può essere consultata sul sito: www.proel.com Prodotto notificato in Italia .
  • Page 13: Safety Instructions

    RMW8 Stage wireless microphone systems Country code Frequency range Codice paese Frequenze autorizzate FR,PL,HU,BE,CH,IT,NL,LU,DE,FIN 470.000 , 786.000 823.000, 826.000 all other countries please your national frequency authority for information on available legal frequencies and legal use Safety Instructions CAUTION: To reduce the risk of electric shock do not the remove cover or back panel. No user serviceable parts inside. Refer servicing to qualified personnel only.
  • Page 14 RMW8  If the supplied AC power cable plug is different from the wall socket, please contact an electrician to change the AC power plug. Grounding or Polarization:  All precautions must be observed to do not defeat grounding or polarization. ...
  • Page 15 Do not attempt to open or to repair this unit by yourself. For any problems not described in this owner’s manual, please refer to qualified personnel only or consult PROEL or your National PROEL Distributor. Any improper operation could result in fire or electric shock.
  • Page 16 In case of interference from source signal, the THD value will raise over 10%. Do not place this unit in confined spaces.  PROEL S.p.A. is not responsible for any damage that occurs due to a incorrect installation of the unit.
  • Page 17: Description

    RMW8 Thank you for choosing this PROEL product and for your trust in our brand, synonymous of professionalism, accuracy, high quality and reliability. All our products are CE approved and designed for continuous use in professional systems. 2. Description The RMW8 Wireless Microphone system features 3 units: The RMW8 receiver, WMP handheld transmitter and WHL body pack transmitter.
  • Page 18: B) Rear Panel Rmw8

    RMW8 b) Rear Panel RMW8 1. UP / DOWN In manual selecting mode, use the Up key to scan the frequency presets from 0 to 99 and Down key from 99 to 0. 2. Menu Keep pressing the Menu key for 1,5 seconds , it comes to the SQ mode. 3.
  • Page 19: D) Body Pack Transmitter Whl

    RMW8 d) Body Pack Transmitter WHL 1. Display LCD displays: antenna symbol (when TX and RX are couplet), operating frequency, charge battery level, CHANNEL, power transmission (PL), LOCK 2. CH/ON Pressing for one second to switch on the transmitter. The transmitter displays the current frequency, the battery charge level. Press again to pass in a cyclic mode the following functions: CHANNEL / PL / LOCK.
  • Page 20: Operation

    RMW8 4. Operation a) Receiver RMW8 Squelch Control Enter SQUELCH mode pressing the MENU key, the symbol with the current level value is displayed: Number Squelch threshold 95,0 dB 91,7 dB 88,3 dB 85,0 dB AUDIO MET ER dB RF MET ER 81,7 dB 78,3 dB 75,0 dB...
  • Page 21: Installation

    RMW8 Mute function Pressing the select key for more than one second will activate the mute function, the word Mute word displayed. Pressing SELECT again will deactivate the mute function. When MUTE function is active the transmitter does not transmit. Battery When batteries are exhausted, the battery level indicator will light.
  • Page 22: Frequency Table (798.000-827.000Mhz)

    RMW8 6. Frequency Table (638.000-658.000mhz) CH 0 CH 1 CH 2 CH 3 CH 4 CH 5 CH 6 CH 7 CH 9 CH 10 CH 11 798.125 798.325 798.525 798.725 798.925 799.125 799.325 799.525 799.725 799.925 800.125 800.325 CH 12 CH 13 CH 14 CH 15...
  • Page 23 The product is in compliance with Directive 89/336/EEC (Electromagnetic Compatibility) and following modifications 92/31/EEC and 93/68/EEC It is also in compliance with Directive 73/23/EEC (Low Voltage) and following modifications 93/68/EEC. PROEL S.p.A hereby, declares that this wireless microphone system complies with the essential requirements and other relevant provisions of Directive 1999/5/EC.
  • Page 24 PROEL S.p.A. (World Headquarters - Factory) Via alla Ruenia 37/43 64027 Sant’Omero (Te) – Italy Tel: +39 0861 81241 Fax: +39 0861 887862 E-mail: info@proel.com www.proel.com...

This manual is also suitable for:

Rmw8mRmw8

Table of Contents