Sine-Wave Filter - Siemens SINAMICS G120 PM240P-2 Installation Manual

Frequency converters
Table of Contents

Advertisement

Spare parts and accessories
7.2 Optional accessories
7.2.4

Sine-wave filter

The sine-wave filter limits the voltage gradient and the capacitive recharging currents which
generally occur in converter operation. Therefore, when a sine-wave filter is used, longer
screened motor cables are possible and the motor lifetime reaches the same values which
are achieved when the motor is connected directly to the mains.
When using a sine-wave filter, observe the following restrictions:
● Operation is only permissible with pulse frequencies from 4 kHz ... 8 kHz (sine-wave filter
from 160kW only 4 kHz).
● It must be ensured that the automatic pulse frequency reductions are deactivated.
● The converter power is reduced by 5%.
● The output frequency must not exceed 150 Hz.
● Operation and commissioning may only be performed with the motor connected because
the sine-wave filter is not no-load proof.
● An output reactor is not required.
NOTICE
Damage to the sine-wave filter if it is not activated during commissioning
The sine-wave filter may be damaged if it is not activated during commissioning.
• Activate the sine-wave filter during commissioning via parameter p0230.
• Activate the sine-wave filter during commissioning according to the electric
Assignment table
Power Module, 400 V
Frame size
Article number
FSD
6SL3210-1RE24-5 .L0
6SL3210-1RE26-0 .L0
6SL3210-1RE27-5 .L0
FSE
6SL3210-1RE28-8 .L0
6SL3210-1RE31-1 .L0
FSF
6SL3210-1RE31-5 .L0
6SL3210-1RE31-8 .L0
6SL3210-1RE32-1 .L0
6SL3210-1RE32-5 .L0
86
specifications.
Sine-wave filter
Power [kW]
Article number
22
6SL3202-0AE24-6SA0
30
6SL3202-0AE26-2SA0
37
6SL3202-0AE28-8SA0
45
6SL3202-0AE28-8SA0
55
6SL3202-0AE31-5SA0
75
6SL3202-0AE31-5SA0
90
6SL3202-0AE31-8SA0
110
6SL3000-2CE32-3AA0
132
6SL3000-2CE32-3AA0
Hardware Installation Manual, 06/2020, A5E37800827C AD