  • Page 1 Surface Is. ASL-E42ASX ASL-E48ASX...
  • Page 2 www.zephyronline.com HOTTE PER CUISINE - Notice d’utilisation...Pag. 23 CAMPANA EXTRACTORA - Manual de utilización...Pag. 45 CAPPA ASPIRANTE - istruzioni per l’uso...Pag. 67 - 2 -...
  • Page 3: Table Of Contents

    SAFETY INSTRUCTIONS...pag. 4 LIST OF MATERIALS...pag. 7 DUCTING CALCULATION SHEETS...pag. 8 HOOD SPECIFICATION...pag. 9 INSTALLATION - INTERNAL BLOWER...pag. 10 - EXTERNAL & IN-LINE BLOWER PREPARATION...pag. 12 - DUCTING OPTIONS...pag. 14 - MOUNTING THE RANGE HOOD...pag. 15 - POWER SUPPLY CONNECTION...pag. 18 MAINTENANCE...pag.
  • Page 4: Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. Take care when using cleaning agents or detergents.
  • Page 5 settings. B. Always turn hood ON when cooking at high heat or when fl ambeing foods ( i.e. Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè ). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or fi lter. D.
  • Page 6 through the fl ue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer’s guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities.
  • Page 7: List Of Materials

    Duct Cover Ceiling Bracket Support Frame Assembly Control Range Hood Body TYPE Blower Housing Light Bulbs Decorative Mesh Filters DESCRIPTION 1/8" x 1/4" 1/4" x 2-3/4" M4 x 9/16" - 7 - Duct Covers N° 1 + 1...
  • Page 8: Ducting Calculation Sheets

    www.zephyronline.com Maximum Duct Length: For satisfactory air movement, the total duct length should not exceed 100 equivalent feet. - 8 -...
  • Page 9: Hood Specification

    side of hood front of hood top of hood - 9 -...
  • Page 10: Internal Blower

    The following instructions are for installing the internal blower. CAUTION: To reduce the risk of fi re and electric shock, install this range- hood only with internal blower models MT-020 provided with the kit cod CBI-600A. For external and in-line blower preparation please turn to page 12.
  • Page 11 6. Attach the 6 pin male molex connector from blower wire to the 6 pin female molex con- nector located inside the blower housing. See Fig.6 7. Install the motor and bracket, inside the motor housing, completing the installation using the other screws (6 type B) that have been sup- plied.
  • Page 12: External & In-Line Blower Preparation

    The following instructions are for preparing the hood for use with an ex- ternal or in-line blowers models CBE-1000 or PBN-1000A. CAUTION: To reduce the risk of fi re and electric shock, install this rangehood only with remote blowers rated maximum 6.2 A. For internal blower instructions please turn to page 10.
  • Page 13 Note1: A cable lock (not included) may be re- quired by local codes. Please review local co- des for more information. 6. Reinstall the cover on the motor housing by following the instructions from step 2 in re- verse order. 7.
  • Page 14: Ducting Options

    www.zephyronline.com WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating op- tion. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certifi ed Silver Tape or Duct Tape.
  • Page 15: Mounting The Range Hood

    MOUNTING HEIGHTS The range hood must be installed at a minimum height of 24 inches (61 cm) from the cooking surface. If a connecting duct work composed of two parts is used, the upper part must be placed outside the lower part. Do not connect the range hood duct to the same duct used to exhaust hot air or fumes from another appliance.
  • Page 16 2. Secure the top support frame to the duct cover ceiling bracket by using the (4 type B) screws. Fig. 10 4. Lift the hood assembly to the cei- ling and align the top support fra- me and ceiling bracket with the (3) screws previously installed in the ceiling.
  • Page 17 5. Insert the bottom support frame into the top support frame. Fig.12 Adjust height according to your in- stallation and secure the support frames together using (2 type B) screws per extension arm (8 total). Fig.13 6. Insert the motor housing into the support frame assembly and secure it using (8 type B) screws.
  • Page 18: Power Supply Connection

    GENERAL • Carefully read the following important information regarding installation safety and maintenance. Keep this information booklet accessible for further consultations. POWER SUPPLY CONNECTION For connection to the power supply refer to the following: 8. Break out the partially pre-cut circle in the cover of the mains power connection en- closure using a fl at head screwdriver.
  • Page 19 11. Replace the lid by following the instructions from step 9 in reverse order, en- suring that the tab on the lid is within the enclosure. 12. Having connected the equipment to the power supply, you can now continue with the ceiling mounting instructions. 13.
  • Page 20: Maintenance

    www.zephyronline.com MAINTENANCE • It is recommended to operate the appliance prior to cooking. It is recommended to leave the appliance in operation for 5 minutes after cooking is completed in order to completely eliminate cooking vapors and odors. The proper function of the range hood is conditioned by the regularity of maintenance.
  • Page 21: List Of Parts And Accessories

    DESCRIPTION REPLACEMENT PARTS Light Bulb GU4, 20W (each) OPTIONAL ACCESSORIES Recirculating Kit Replacement Charcoal Filters Duct Cover Extension (12” ceiling) To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368 HOOD Z0B0030 ZRC-00SL Z0F-00AC Z1C-00SL - 21 - PART#...
  • Page 22 www.zephyronline.com - 22 -...
  • Page 23 3LIK0510...