5.1.7 Moving the dentist element and assistant element into treatment position ....24 5.1.8 Switching off the DSE Compact 5195 / 5195 LUX and moving it to park position ..24 5.2 Using triple-function handpieces ..................26 3 / 40...
Page 4
Instructions for use DSE Compact 5195 / 5195 LUX Table of contents 5.3 Using the turbine ......................28 5.4 Foot control C (standard)....................28 5.5 Using the spray mist suction device and saliva ejector ............29 6 Reprocessing methods according to DIN EN ISO 17664 ........... 30 6.1 Servicing ........................
Instructions for use DSE Compact 5195 / 5195 LUX 1 User instructions | 1.1 User guide 1 User instructions 1.1 User guide Requirement Read these instructions prior to first startup to avoid misuse and prevent dam- age. 1.1.1 Abbreviations Explanation...
12 months from the date of purchase as confirmed by the sales- person. In case of justified complaints, KaVo will honour its warranty with a free re- placement or repair. The warranty does not cover defects and their consequences that arose or may...
Terms and Conditions, Art. 28). Outside Germany Note KaVo shall not be held liable for damage arising from transportation. The shipment must be checked on arrival. If the packaging is visibly damaged on delivery, please proceed as follows: 1. The recipient of the package must record the loss or damage on the delivery receipt.
Page 8
Instructions for use DSE Compact 5195 / 5195 LUX 1 User instructions | 1.4 Transportation and storage Protect from moisture! Permissible stacking load Temperature range Humidity Air pressure 8 / 40...
Instructions for use DSE Compact 5195 / 5195 LUX 2 Safety | 2.1 Description of safety instructions 2 Safety 2.1 Description of safety instructions 2.1.1 Warning symbol Warning symbol 2.1.2 Structure DANGER The introduction describes the type and source of the hazard.
DANGER Explosion hazard. Risk of fatal injury. ▶ Do not use KaVo product in areas subject an explosion hazard. WARNING Injury or damage from damaged functional parts. If functional parts are damaged, it can cause additional damage or personal in- jury.
KaVo product for the intended purpose are to be applied and complied with. The use of this KaVo product is not permitted in areas subject to an explosion hazard.
Instructions for use DSE Compact 5195 / 5195 LUX 3 Description of the product | 3.2 Overview 3.2 Overview ① Assistant element (if present) ② Dental patient simulator ③ Main switch ④ Foot control ⑤ Tray ⑥ Dentist element ⑦ Effluent tank ⑧...
REF: 1.009.6200 Input: 9 - 15V 3 VA Made in China Made in China Type Device type DSE Compact 5195 / DSE Compact 5195 LUX Serial number Material number CE mark NRTL mark Follow the instructions for use! For disposal information, see Intended use Follow the instructions for use! 3.6 Technical Specifications...
Page 14
Instructions for use DSE Compact 5195 / 5195 LUX 3 Description of the product | 3.6 Technical Specifications Dimensions in park position Width 360 mm Height 785 mm Depth 595 mm Weight 61 kg Media Note Connections to drinking water lines must comply with local, national regula- tions.
Ambient temperature -20 to +55 C / -4 to +131°F Relative humidity 5% to 95% non-condensing Air pressure 700 to 1,060 hPa 3.7 Scope of delivery Basic device DSE Compact 5195 / 5195 LUX (depending on model) 15 / 40...
Instructions for use DSE Compact 5195 / 5195 LUX 4 Commissioning | 4.1 Fitting and connecting 4 Commissioning 4.1 Fitting and connecting 4.1.1 Connect power, air and water Note Connect the device only to an external power supply approved according to IEC 60950 that has the appropriate voltage and power specifications.
Instructions for use DSE Compact 5195 / 5195 LUX 4 Commissioning | 4.1 Fitting and connecting ▶ Power connection (depending on model): plug the enclosed power supply into the connector on the device and then into the electrical outlet. ▶ Depending on the model, connect to the central suction unit.
Instructions for use DSE Compact 5195 / 5195 LUX 4 Commissioning | 4.1 Fitting and connecting 4.1.3 Installing the handpieces ▶ Install the handpieces as outlined in the instructions. See also: 2 Instructions for Use of the handpiece Install triple function handpiece NOTICE Damage caused by non-axial attachment.
Instructions for use DSE Compact 5195 / 5195 LUX 4 Commissioning | 4.1 Fitting and connecting ▶ Connect the triple function handpiece to the hose connector. See also: 2 4.1.4 Connect the handpieces, Page 19 4.1.4 Connect the handpieces ① Turbines or air motors ②...
Instructions for use DSE Compact 5195 / 5195 LUX 5 Operation | 5.1 Operation in general 5 Operation 5.1 Operation in general 5.1.1 Positioning the DSE Compact 5195 / 5195 LUX Note Do not push the patient simulator downwards with force. Device may tilt.
Page 21
Instructions for use DSE Compact 5195 / 5195 LUX 5 Operation | 5.1 Operation in general ▶ Manual brake: Press the brake ③ on the two front castors by foot. Pneumatic break: Actuate brake switch ②. ð The chassis is braked.
Instructions for use DSE Compact 5195 / 5195 LUX 5 Operation | 5.1 Operation in general 5.1.2 Positioning the head of the patient simulator The head of the dental patient simulator can perform the following movements: ▪ approx. 25 forward nodding movement ▪...
See also: 2 6.1.2 Filling the pressurised water system (if available), Page 31 5.1.6 Switching on the DSE Compact 5195 / 5195 LUX ▶ Switch on the DSE Compact 5195 / 5195 LUX using the main switch. 23 / 40...
▶ Moving the dentist element and assistant element ① into treatment posi- tion. For this purpose, grasp the handpiece arm by the tube ② or on the dentist or assistant element. 5.1.8 Switching off the DSE Compact 5195 / 5195 LUX and moving it to park position CAUTION Connecting lines from the simulation unit to the customer-site supply connectors.
Page 25
Instructions for use DSE Compact 5195 / 5195 LUX 5 Operation | 5.1 Operation in general Note Always unplug the power supply when the simulation unit is not in use. Requirement The treatment / practice with the simulator is completed.
Instructions for use DSE Compact 5195 / 5195 LUX 5 Operation | 5.2 Using triple-function handpieces 5.2 Using triple-function handpieces Syringe DCI 3439 ① Cannula ② Water button ③ Air button Triple function handpiece One ① Cannula ② Water button (green ring) ③...
Page 27
Instructions for use DSE Compact 5195 / 5195 LUX 5 Operation | 5.2 Using triple-function handpieces Triple function handpiece ① Cannula ② Water button (W) ③ Air button (A) ④ Gripping sleeve Note The cannulas can be rotated 360 ▶ Remove the turbine from the holder.
Instructions for use DSE Compact 5195 / 5195 LUX 5 Operation | 5.3 Using the turbine 5.3 Using the turbine Note Follow the Instructions for Use, service instructions and installation instruc- tions in the instrument packaging. Note The light of the DSEcompact 5195 LUX is on only if the handpiece is taken out and the foot control is actuated simultaneously.
Instructions for use DSE Compact 5195 / 5195 LUX 5 Operation | 5.5 Using the spray mist suction device and saliva ejector ð Water is turned off. Actuate the patient positioning button ▶ Press the patient positioning button. ð This unlocks the swivel arm mechanism.
Instructions for use DSE Compact 5195 / 5195 LUX 6 Reprocessing methods according to DIN EN ISO 17664 | 6.1 Servicing 6 Reprocessing methods according to DIN EN ISO 17664 6.1 Servicing Note Repair and servicing work on the electrical part of the unit may be done only by skilled staff or by staff trained in the factory.
Instructions for use DSE Compact 5195 / 5195 LUX 6 Reprocessing methods according to DIN EN ISO 17664 | 6.2 Care 6.1.2 Filling the pressurised water system (if available) CAUTION The bottle is sensitive to heat. Material fatigue. ▶ Do not rinse the bottle in the dish washer or with hot water (above 50 Requirement The bottle is empty.
▪ the applicable accident prevention regulations. The overarching guidelines and/or national laws, national regulations and the rules of technology applicable to this product for start-up and use of the KaVo product for the intended purpose are to be applied and complied with.
Instructions for use DSE Compact 5195 / 5195 LUX 8 Troubleshooting 8 Troubleshooting Malfunction Cause Remedy Suction power of saliva ejector is Spray mist extractor is not Close spray mist extractor. insufficient. closed. Triple function handpiece does Compressed air shut-off valve is Open the shut-off valve.
Instructions for use DSE Compact 5195 / 5195 LUX 9 Accessories 9 Accessories Accessories The accessories listed below are optional and can be supplied depending on unit model. BS = kit Figure Description Material number DSEplus neurocranium Mat. no. 1.000.2616 Air handpiece hose Mat.
Page 35
Instructions for use DSE Compact 5195 / 5195 LUX 9 Accessories Figure Description Material number EBS Preparation for first Mat. no. 2.000.1521 pneumatic handpiece in- stallation kit EBS Preparation for Mat. no. 2.000.1706 second pneumatic hand- piece installation kit EBS Triple function hand- Mat.
Page 36
Instructions for use DSE Compact 5195 / 5195 LUX 9 Accessories Figure Description Material number Cranium denture G20 Mat. no. 1.003.9307 Simulation model UJ VZ Mat. no. 0.623.0401 Simulation model LJ VZ Mat. no. 0.623.0411 Simulation model UJ TZ Mat. no. 0.623.0531 Simulation model LJ TZ Mat.