4

Mechanical installation

4.1
Parabolic antenna
4.1.1
Mounting the clamped Flange Ball
Follow this instruction when installing the clamped Flange Ball on a flange.
Prerequisites
1. Use a flange of thickness 6 - 30 mm.
2. Make sure that the diameter of the hole is 96 mm. Make a small
recess at one side of the flange hole.
Figure 4-1: Flange Requirements
A. Recess