Operation of the device
5.4 Menu "out"
5.4.1 Configuration of the relay operating mode
Relay K1
Relay K2
Display
FAC
Ke
Display
n.c.
1
2
FAC = Factory setting; Ke = Customer settings
5.4.2 Relay alarm assignment "r1" and "r2" and LED assignment
In the alarm assignment, each alarm is assigned to the respective relay with the setting
"on". The LED indication is directly assigned to the alarms and is not related to the relays.
In the event of an unsymmetrical insulation fault, only the alarm corresponding to the as-
signed conductor (L+ or L-) will be displayed.
K1 „r1"
K2 „r2"
Display
FAC
Ke
Display
off
2
Err
1
Err
r1
r2
on
+R1 < Ω
+R1 < Ω
r1
r2
on
-R1 < Ω
-R1 < Ω
r1
r2
off
+R2 < Ω
+R2 <Ω
r1
r2
off
-R2 < Ω
-R2 < Ω
r1
r2
off
U < V
U < V
r1
r2
off
U > V
U > V
r1
r2
off
test
test
r1
r2
off
S.AL
S.AL
FAC = Factory setting; Ke = Customer settings
: LED off
: LED flashes
: LED on
17
Description
FAC
Ke
n.c.
Operating mode of the relay n.c./n.o.
LEDs
description
FAC
Ke
ON
AL1
AL2
on
Device error E.xx
Pre-alarm R1
off
Fault R
Pre-alarm R1
off
Fault R
Alarm R2
on
Fault R
Alarm R2
on
Fault R
Alarm U
on
Undervoltage
Alarm U
on
Overvoltage
Manually
off
started
device test
Device start with
off
alarm
Operation of the device
5.4.3 Fault memory configuration
Display
FAC
M
off
FAC = Werkseinstellung;
5.4.4 Interface configuration
Display
Value range
Adr
0/3...90
--- /
Adr 1
1.2k ... 115k
Alarm
8E1
Adr 2
8o1
at L+
8n1
F
at L-
F
FAC = Factory settings; Ke = Customer settings;
at L+
( ) = User setting that is not modified by FAC.
F
5.5 „t" menu
at L-
F
n
5.5.1 Time configuration
n
Display
Value range FAC
t
0 ... 10
ton
0 ... 99
toff
0 ... 99
test
OFF/1/24
FAC = Factory setting; Ke = Customer settings
Ke
Description
Memory function for alarm messages (fault memory)
Ke = Kundeneinstellungen
Setting value
FAC
Ke
Adr = 0 deactivates BMS as well as Mod-
bus and activates isoData with conti-
3
(
) BusAdr.
nuous data output
(115k2, 8E1)
"---"
"---" (
) Baud rate
"1.2k" ... "115k" --> Modbus (variable,
8E1 - 8 data bits
even parity, 1 stop bit
8o1 - 8 data bits
8E1
(
)
odd parity, 1 stop bit
8n1 - 8 data bits
no parity, 1 stop bit
Setting value
Ke
0
s Start-up delay when starting the device
0
s Response delay K1 and K2
0
s Delay on release K1 and K2
24
h Repetition time device test
isoCHA425_D00352_01_M_XXEN/10.2019
Description
--> BMS-Bus (9k6, 7E1)
variable)
Description

Advertisement

loading
Need help?

Need help?

Do you have a question about the ISOMETER isoCHA425 and is the answer not in the manual?

Questions and answers