STEP 1
Standard Mounting
(Recommended)
STEP 1A
Alternate Mounting
STEP 2
Install/Mount Charger
STEP 3
Set Amp Switch
STEP 4
Close the Charger
8
1. Locate a stud within the wall that can handle the 14+ lb. load of the VersiCharge.
2. Place the mounting bracket not more than 12" above a 240 V outlet; level the mounting and drill the center-top hole using
aathe drill with an extender.
3. Secure the mounting with the kit-supplied screws.
4. Drill the bottom hole using the bottom-center mounting hole as a guide.
5. Secure with the kit-supplied screw.
6. Tighten both top and bottom screws securely.
For other walls, install appropriate anchors. If using an existing outlet, ensure that power cord will reach to the outlet. Using
a 7/16" socket, attach mounting bracket to wall in compliance with all National Electrical Code® (NEC) and local jurisdiction
requirements, using the 2 lag screws provided.
NOTE: Anchors must be rated for at least 100 lbs. (4 -25 lb. rated anchors).
The VersiCharge can be mounted using 4 - #12 x 1-½ LG Phillips head 0.375 head minimum with 4 - #10 – 14 wall anchors.
1. Locate the mounting bracket not more than 12" above a 240 V outlet or if hardwiring, the wiring will come through the
bottom of the charger.
2. Level the mounting bracket and drill 4 holes, one in each corner of the bracket.
3. Place anchors into the wallboard until they are flush with the wall.
4. Place the mounting bracket over the holes (hinges facing upward, flat side of the bracket against the wall) with the
anchors and screw the mounting to the wall securely.
NOTE: For installation, the mounting-bracket hinges will be pointing to the ceiling, and the flat side of the bracket will be
against the wall.
1. Slide the VersiCharge on to the hinges.
2. Rotate to the right until the unit clicks and is closed.
3. Secure the enclosure with the locking mechanism and plug the VersiCharge into the 240 V outlet. If hardwiring the unit,
aasee Hardwire Installation in Step 7.
DANGER Hazardous voltage. Will cause death or
serious injury. Turn off power before working on this
equipment. This indicates a situation where the present
voltage could cause injury or death. Extreme caution is
required when servicing or installing the equipment
referenced.
The VersiCharge comes set to the maximum of the model purchased (i.e. a 40 amp model will not exceed 40 amps but may be
derated for lower amperage by using the amperage adjustment dial). See Figure 7.
Amperage Settings
Switch
Positionwitch
Amps
Position
0
12
1
16
2
24
3
32
4
40
5
48
NOTE: Setting the amp switch higher than #5 will cause a bad switch fault.