Z-Com ZMAX-8210-E User Manual

Zmax-8210 series
Table of Contents

Advertisement

Quick Links

ZMAX-8210 Series
(ZMAX-8210-I/ZMAX-8210-E)
User's Manual
V2.0.6.0

Advertisement

Table of Contents
loading

Summary of Contents for Z-Com ZMAX-8210-E

  • Page 1 ZMAX-8210 Series (ZMAX-8210-I/ZMAX-8210-E) User’s Manual V2.0.6.0...
  • Page 2: About This Manual

    This user’s manual and the software described in it are copyrighted with all rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means without the written permission of Z-Com Corporation. About This Manual This manual explains Z-Com outdoor ZMAX-8210 Customer Premise Equipment (CPE), how to build the infrastructure centered on the ZMAX-8210 and proposals when using this CPE.
  • Page 3: Table Of Contents

    Chapter 1 Introduction... 1 ... 1 NTRODUCTION ... 1 PPEARANCE ... 2 EATURES UILD YPICAL NFRASTRUCTURE ... 4 YPICAL Chapter 2 Basic Installation... 5 YSTEM EQUIREMENT ... 5 ACKAGE ONTENT ARDWARE NSTALLATION NTENNA NSTALLATION Chapter 3 Basic Settings... 8 EFAULT ACTORY ETTINGS OW TO...
  • Page 4 Appendix A Specifications... 31 Appendix B Technical Terms ... 37 Appendix C ASCII ... 39 Appendix D SSH Settings... 41 - IV -...
  • Page 5 Figure Figure 1 ZMAX-8210... 1 Figure 2 ZMAX-8210 ports... 2 Figure 3 Wireless Point-to-Point Outdoors... 3 Figure 4 Wireless Point-to-multipoint Outdoors ... 4 Figure 5 Safety Alert ... 9 Figure 6 Login ... 9 Figure 7 ZMAX-8210 General Information ... 10 Figure 8 ZMAX-8210 CPE Name...
  • Page 6 Table Table 1 ZMAX-8210 Default Factory Settings ... 8 Table 2 ZMAX-8210-I Spec... 31 Table 3 ZMAX-8210-E Spec... 33 Table 4 Technical Terms ... 37 Table 5 ASCII ... 39 Table 6 SSH Settings ... 41 - VI -...
  • Page 7: Chapter 1 Introduction

    ZMAX-8210-I build in 16dBi gain antenna, ZMAX-8210-E with N-Female connector for external antenna. Typically, 802.11s Mesh implemented in this device will free physical limitation that a block stands in the way in the infrastructure could lead to failure of communication), finding a key to “the last mile”.
  • Page 8: Key Features

    The ZMAX-8210 appearance is designed to be water-proof and dust-proof for most challenging environments outdoors. Key Features The ZMAX-8210 provides you with the solid features. Power supply via POE Based on WiMAX together with compliant with 802.16d-2004 Work at 3.5GHz Implement Orthogonal Frequency Division Multiplexing (OFDM)...
  • Page 9: Figure 3 Wireless Point-To-Point Outdoors

    Figure 3 Wireless Point-to-Point Outdoors Under this structure, the ZMAX-8210 acts as a customer premise equipment (CPE), connecting a WiMAX Base Station. Wireless Point-to-multipoint Outdoors Under this structure, acting as a customer premise equipment, the ZMAX-8210 is connected to the WiMAX Base Station, allowing ISP to cost-effectively build infrastructure in a matter of hours.
  • Page 10: Typical Case

    Figure 4 Wireless Point-to-multipoint Outdoors Typical Case The high-quality performance enables the ZMAX-8210 to gain widespread acknowledgements. It is able to undertake tasks in various situations. Create or expand well-created network via this CPE in enterprises or residential quarters Provide an access to Metropolitan Area Network via WLAN Act as a media connecting Base Station and sub-stations in mobile communicating network Provide an access to hard-to-reach areas, like ancient sites Cost-effectively build in most challenging environments, like remote mountain areas and rough...
  • Page 11: Chapter 2 Basic Installation

    Hardware Installation Follow the steps below to install your ZMAX-8210. (the different of hardware installation between ZMAX-8210-I and ZMAX-8210-E is antenna) Make sure all components linked to the ZMAX-8210 are on hand. A brace fixed on the back of the ZMAX-8210 is tabled on a perfect area like well-sized desk.
  • Page 12 Connect the other end of the Ethernet cable to the ZMAX-8210. Tighten the water-proof connector. A ground wire connects the ZMAX-8210. Note: To keep the ZMAX-8210 antenna intact, a plastic coat is over the antenna. Remove the coat wile using it. Warning:...
  • Page 13: Antenna Installation

    Antenna Installation 16dBi built-in antenna is placed in the ZMAX-8210, so you need not install antenna. The ZMAX-8210-E needs an external antenna. You should choose your antenna as your need. Warning: Keep your ZMAX-8210 associated with the antenna away from power line, lamp, electrified wire fence or anything others electrified.
  • Page 14: Chapter 3 Basic Settings

    Chapter 3 Basic Settings Default Factory Settings We’ll elaborate the ZMAX-8210 default factory settings. You can re-acquire these parameters by resort button. If necessary, please refer to the “the way to restore default factory settings. Table 1 ZMAX-8210 Default Factory Settings Feature User Name Password...
  • Page 15: Figure 5 Safety Alert

    Clicking “Yes” ushers you into the login. Note: Make sure the PC IP address need to be matched the device. For instance, the ZMAX-8210 is 192.168.1.1, and your PC IP should be 192.168.1. X. Enter the default name “admin” in the username field and “password” in the password field。Clicking “...
  • Page 16: Device Name

    Figure 7 ZMAX-8210 General Information Device Name Clicking“Basic Settings” ,you’ll see the ZMAX-8210Name. You may assign any device name to this CPE. This name is only used by the CPE administrator for identification purposes. Unique, memorable names are helpful, especially if you are employing multiple access points on the same network. This name is composed of 15 characters with 0-9, A-Z, a-z or “-“.
  • Page 17: Bridge And Router Mode

    By default, the ZMAX-8210 CPE is Devicexxxxxx(xxxxxx represents the last 6 digits of MAC address). No figure is allowed to represent initial. When WINS undertakes interpreting, make sure the PC IP address need to be matched the CPE. For instance, the ZMAX-8210 is 192.168.1.1, and your PC IP should be 192.168.1.
  • Page 18: Wireless Parameters

    If you fail to obtain IP address for the ZMAX-8210, the CPE will turn to the client address for use. Wireless Parameters Opening“Radio Settings can lead you to the ZMAX-8210 wireless parameters. You can set what you desire. Figure 10 ZMAX-8210 Wireless Parameters Base Station ID:...
  • Page 19: Create A Link Between The Zmax-8210 And Wimax Base Station

    devices. Encryption:This field provides encryption options. Note: When the communication is established, the encryption shall be completely identical between the ZMAX-8210 and the Base Station, IR Bit:This field identifies whether forward “initial ranging data” 。 Note: There shall be in complete accord in the parameters between IR Bit and Base Station.
  • Page 20 The parameters set in the ZMAX-8210 shall match the ones in the WiMAX Base Station, when the tie is established. Using “ping” to check whether the communication is sound. Take an example as follows. Ping 192.168.1.1 to check the communication between the ZMAX-8210 and PC. 192.168.1.200 check the communication between the ZMAX-8210 and WiMAX Base Station.
  • Page 21: Chapter 4 Advanced Configuration

    Chapter 4 Advanced Configuration Router Mode The ZMAX-8210 is able to carry out router function. Opening“IP Settings”navigates you to router mode interface. Figure 12 ZMAX-8210 Router Mode Settings You can set proper IP addresses for WAN and LAN. Refer to the following infrastructure. Chapter 4 Advanced Configuration - 15 -...
  • Page 22: Any Ip

    Any IP Under the router mode, the ZMAX-8210 provides Any IP,enabling you to enter whatever IP addresses legally or illegally so as to carry out various tasks, relieving your trouble of memorizing IP address. Take the steps below. From the“IP Settings” ,Choose“Router”and enable“Enable Any IP”. Note:...
  • Page 23: Dhcp Server

    DHCP Server Under the router mode, the ZMAX-8210 can also serve as a DHCP server, responsible for assigning IP addresses to the devices connected to the infrastructure. From the “ IP Settings” choose “ Router”. The way to assign IP Address turns “Static IP to “DHCP Server”.
  • Page 24: Http Redirect

    From the“Adjust for Daylight Saving Time” ,you have the option of daylight saving time or not. Finally, clicking “Apply” to complete your time server settings. Note: It is only when the ZMAX-8210 have access to the internet that the time server can take effect.
  • Page 25: Figure 18 Http Redirect

    From PC1,PC2 or PC3, you want to login the internet-- http://www.sohu.com,but the web browsers will turn to http://www.zcom.com.tw;If from the PCs to browse http://www.sohu.com anew, this time you’ll see the exact page. Note: Make sure there is an access from the ZMAX-8210 to the internet, before enabling HTTP Redirect.
  • Page 26: Chapter 5 Management

    Chapter 5 Management View the ZMAX-8210 Basic Information From the“Information” ,the ZMAX-8210 provides the basic information about this CPE. All is read-only. For the detailed information, refer to Basic Settings Advanced Configuration.。 Figure 19 Basic Information View Statistics Information From the“Statistics” ,the ZMAX-8210 provides information about sending or receiving packets out of both the Ethernet and wireless ports.
  • Page 27: Password

    Figure 20 ZMAX-8210 Statistics Information The Ethernet port provides the packet information from the Ethernet port. The wireless port provides the packets information from the wireless port. Password You can change password to managing your ZMAX-8210. The length of password is no more than 19 characters. You can restore the default password by enabling “Restore Default Password”.
  • Page 28: Backup And Retrieve

    Click“Upload”to enable the file to be loaded to your ZMAX-8210. Reboot your ZMAX-8210 and check whether the firmware has been upgraded in the Basic Information. Upgrade firmware via FTP Enter the command ftp 192.168.1.1,admin and password. After successful commanding, enter“put mercury.rmt”. If the upgrade is successful, the information will be shown as below.
  • Page 29: Figure 23 Retrieve And Backup Settings

    C:\>ftp 192.168.1.1 Connected to 192.168.1.1 220 (vsFTPd 1.1.3) User (192.168.1.1:(none)): admin 331 Please specify the password. Password: 230 Using binary mode to transfer files. Login successful. Have fun. ftp> get mercury.cfg 200 PORT command successful. Consider using PASV. 150 Opening BINARY mode data connection for /mnt/ramd/ mercury.cfg (11411 bytes). 226 File send OK.
  • Page 30: Restore Factory Default Settings

    The file name shall be mercury.cfg. Restore Factory Default Settings The ZMAX-8210 provides two ways to restore the default factory settings. Restore the factory default settings via web: From the “Restore Factory Default Settings”, clicking “ Restore ” will restore your ZMAX-8210 default settings.
  • Page 31: Figure 26 Putty Settings

    Figure 26 Putty Settings From the “Connection”, select “SSH”; From the “Preferred SSH protocol version”, select “2” ; From the “Encryption cipher selection policy”, make“3DES”the top position. Chapter 5 Management - 25 -...
  • Page 32: Figure 27 Putty Settings 2

    Figure 27 Putty settings 2 Click Open and a page will open like below: Figure 28 SSH Settings 3 Enter admin and password in the separate field. For help information, enter” help” command. Chapter 5 Management - 26 -...
  • Page 33 Chapter 5 Management - 27 -...
  • Page 34: Chapter 6 Troubleshooting

    Chapter 6 Troubleshooting Frequently Asked Question (FAQ) Q 1. In what way to get to know the ZMAX-8210 MAC address? MAC Address distinguishes herself by the distinct identity among networking devices. There are two ways available to know the address. •...
  • Page 35: Figure 30 Zmax-8210 Wireless Network Connection Properties

    Figure 30 ZMAX-8210 Wireless Network Connection Properties Q 5. In what way to restore my ZMAX-8210 to the factory default settings? Refer to Restore Factory Default Settings. Q 6. How to re-gain my ZMAX-8210 password if it slips off my mind? Refer to Restore Factory Default Settings.
  • Page 36: Figure 31 Zmax-8210 Ping

    Figure 31 ZMAX-8210 Ping Chapter 6 Troubleshooting - 30 -...
  • Page 37: Appendix A Specifications

    Appendix A Specifications This appendix provides technical terms for the ZMAX-8210 CPE. Table 2 ZMAX-8210-I Spec 802.16d-2004 Outdoor CPE Module Description System Operation Mode IP Router Access Control Flow Control DHCP HTTP Redirect Watchdog Features Encryption (Dynamic Frequency Selection) Appendix A Specifications Main Features as follows: Operates at 3.5GHz Built-in 16dBi directional panel antenna...
  • Page 38 (Automatic Repeat Request) (Payload Header Suppression) Site Survey Signal Indicators Radio Standard Modulation RF Frequency Bandwidth Duplexing Method Spectral Efficiency Supported Frame Lengths Tx Maximum output Power (at antenna connector) Tx Center Frequency Tolerance Symbol Clock Frequency Tolerance Frequency Control Spectral Mask Requirements Power Control Adjacent Channel Rejection C/I...
  • Page 39: Table 3 Zmax-8210-E Spec

    Power Supply Environment Operating Temperature Operating Humidity Storage Temperature Storage Humidity Waterproof RoHS compliant Warranty Table 3 ZMAX-8210-E Spec 802.16d-2004 Outdoor CPE Appendix A Specifications QPSK 3/4 16QAM 1/2 16QAM 3/4 64QAM 1/2 64QAM 3/4 Web/TFTP/FTP One 10/100-BaseTX RJ-45 Ethernet Port...
  • Page 40 SNMP support RoHS Signal Status Display by LED Line ZMAX-8210-E ZMAX-8210-E works at 3.5GHz, compatible with 802.16d-2004 standard, designed as CPE.. ZMAX-8210-E benefits from WiMAX technologies with OFDM technology, delivering the best economics and advanced wireless solution for fixed broadband access.
  • Page 41 Modulation RF Frequency Bandwidth Duplexing Method Spectral Efficiency Supported Frame Lengths Tx Maximum output Power (at antenna connector) Tx Center Frequency Tolerance Symbol Clock Frequency Tolerance Frequency Control Spectral Mask Requirements Power Control Adjacent Channel Rejection C/I Nonadjacent Channel Rejection C/I Relative Tx Constellation Error (@20.5dBm output power) Maximum Rx Receiver Sensitivity...
  • Page 42 SNMP F/W Upgrade Interface Antenna Default Button Ground Interface Physical Dimension Weight Power Consumption Power Supply Environment Operating Temperature Operating Humidity Storage Temperature Storage Humidity Waterproof RoHS compliant Warranty Appendix A Specifications Web/TFTP/FTP One 10/100-BaseTX RJ-45 Ethernet Port One N Type (Female) Interface 1-Power, 1-WLAN, 1-LAN, 5-Signal Indicator 277(L)x277(W)x80(H) 1.5 Kg...
  • Page 43: Appendix B Technical Terms

    Appendix B Technical Terms Table 4 Technical Terms Terms Description IEEE 802.16 IEEE 802.16 is a wireless networking standard adopted in December, 2001. BS is the abbreviation of Base Station, a basic component in WiMAX infrastructure. SS is the abbreviation of Subscriber Station, a user-client in WiMAX infrastructure.
  • Page 44 device and other devices. Web-based A web-based management. You have access to the site via Netscape or Microsoft Graphical User Internet Explorer, monitoring and managing your device. Interface (GUI) WINS Server WINS. Windows Internet Naming Service is a server process for resolving Windows-based computer names to IP addresses.
  • Page 45: Appendix C Ascii

    Appendix C ASCII WEP can be configured with a 64-bit or 128-bit Shared Key (hexadecimal number or ACSII). As defined, hexadecimal number or ACSII is represented by 0-9, A-F or a-f; likewise, ACSII is represented by 0-9, A-F, or a-f and punctuation. Every can consist of two-digit hexadecimal. Table 5 ASCII ASCII ASCII...
  • Page 46 Appendix C ASCII - 40 -...
  • Page 47: Appendix D Ssh Settings

    Appendix D SSH Settings Table 6 SSH Settings keyword √ √ system √ version √ √ devicename √ macaddr √ √ routemode anyiponrout √ √ √ time √ √ √ √ √ √ √ √ bridge √ √ √ √ √...
  • Page 48 √ √ √ √ √ √ √ √ √ √ √ √ √ √ wireless √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ snmp √...
  • Page 49 √ √ √ √ √ √ wimax √ √ √ √ √ √ √ √ √ √ √ √ √ √ √ password √ reboot √ exit √ quit Appendix D SSH Settings write community description bsid duplex channel cpsize bandwidth framelengh encryption...

This manual is also suitable for:

Zmax-8210-i

Table of Contents