Download Print this page
York MKC-MKH Specifications

York MKC-MKH Specifications

Ceiling cassette split system air conditioners

Advertisement

Quick Links

MINISPLIT : CASSETTE
SPECIFICATIONS
Indoor
Unit
MODELS
Outdoor
Unit
Btu/h
Cooling
kW
kcal/h
Capacities
Btu/h
Heating
kW
kcal/h
Compressor
Type
Refrigerant
V/Ph/Hz
Power Supply
Ph
Power Consumption
kW
Running Current
A
Indoor Air Flow
m
3
/h
Indoor
dBA
Noise Level
Outdoor
System Operation Control
H (mm)
Dimensions
Indoor/Outdoor
W (mm)
D (mm)
Indoor
Net Weight
kgs
Outdoor
Connection Type
Piping
Suction
Size
Liquid
The Nominal Cooling Capacity is based on :
- Indoor Air Temp. 27°C DB / 19°C WB - Outdoor Air Temp. 35°C DB
Piping length : 5m
4 CM.
Panel Thickness
Wireless/Wired Control
Low Profile
Turbo fan
Air filter
4 Way Air flow
PRODUCT:
• Four way air flow system
• Quiet Turbo fan
• Easily detachable grill for cleaning
• Air filter
035T73000-002
MKC-MKH
25
35
45
55
MOC-MOH
25
35
45
55
24,000
32,000
42,000
52,000
7.0
9.4
12.3
15.2
6,060
8,080
10,606
13,131
25,600
32,500
42,800
52,800
7.5
9.5
12.5
15.5
6,465
8,207
10,808
13,333
Reciprocating
R-22
220-240/1/50 or 380-415/3/50
1
3
1
3
3
3
2.8
2.7
3.4
3.3
4.77
5.6
13.0
5.4
16.4
6.8
8.9
11.2
1,260
1,260
1,800
2,100
39/42/44
39/42/44
39/42/44
42/44/48
57
58
60
63
Wired or Wireless Control with LCD Display
290/696
290/900
340/1,142
340/1,142
710/850
710/850
810/850
810/1,060
710/287
710/285
810/285
810/345
36
36
42
44
68
85
90
109
Flare and Nuts
5/8"
5/8"
3/4"
3/4"
3/8"
3/8"
3/8"
3/8"
The Nominal Heating Capacity is based on :
- Indoor Air Temp. 21°C DB - Outdoor Air Temp. 7°C DB/6°C WB
Piping length : 5m
CONTROL:
• Wired or wireless versions available
• Room temperature setting
• 5 Operation modes
• Filter cleaning indicator
(Cool/Heat/Auto/Dry/Fan)
• LCD display with clock
• Sleep mode and independent
• Auto restart memory
on - off Timers
• Diagnostic function with
• 3 speed fan control
LED indicators
CONDENSING UNITS:
• Quiet operation with sound insulating blanket
and rubber mounting on compressor
• High efficiency compressor
• Built-in drain pipe connector
for condensate
(heat pump only)
BE-MK0101-05
Ceiling Cassette
Split System Air Conditioners
cools the biggest and most important buildings.
Gets chosen for the most critical refrigeration projects.
Creates the most comfortable homes.
Sponsors the most watched sporting events.

Advertisement

loading
Need help?

Need help?

Do you have a question about the MKC-MKH and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

This manual is also suitable for:

Moc-moh