Download  Print this page

Yeoman YM-CL3MF Instructions For Use Installation And Servicing

Cl series free standing stove
Hide thumbs

Advertisement

Yeoman CL
Free Standing Stove
Models: YM-CL3MF / YM-CL5W / YM-CL5MF / YM-CL8W / YM-CL8MF
This design is protected under Registered Community Design no's. 001202600-0004 / 001202600-0005 / 001202600-0006

Instructions for Use,

Installation and Servicing
For use in GB & IE (Great Britain and Republic of Ireland).
This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translated
instructions and in some cases the appliance will require modification. Contact Stovax for further information.
IMPORTANT
This appliance will become hot whilst in operation, it is therefore recommended that a suitable guard should be used for the
protection of young children, the elderly or infirm. Do not attempt to burn rubbish in this appliance.
Please read these Instructions carefully before installation or use.
Keep them in a safe place for future reference and when servicing the fire.
The commissioning sheet found on page 3 of these instructions should be completed by the Installer.
PM426 Issue 3 (March 2011)

Advertisement

Table of Contents
loading

  Related Manuals for Yeoman YM-CL3MF

  Summary of Contents for Yeoman YM-CL3MF

  • Page 1: Instructions For Use

    Yeoman CL Free Standing Stove Models: YM-CL3MF / YM-CL5W / YM-CL5MF / YM-CL8W / YM-CL8MF This design is protected under Registered Community Design no's. 001202600-0004 / 001202600-0005 / 001202600-0006 Instructions for Use, Installation and Servicing For use in GB & IE (Great Britain and Republic of Ireland).
  • Page 2: Table Of Contents

    MODELS: YM-CL3MF / YM-CL5W / YM-CL5MF / YM-CL8W / YM-CL8MF APPLIANCE COMMISSIONING CHECKLIST 3 USER INSTRUCTIONS General Points Using the Appliance for the first time Recommended Fuels Lighting the Appliance Running the Appliance Burning Tips Ash Removal Extended Burning Over-Firing...
  • Page 3: Appliance Commissioning Checklist

    APPLIANCE COMMISSIONING CHECKLIST To assist us in any guarantee claim please complete the following information:- Retailer appliance was purchased from Name: ... Address: ... Telephone number: ... Essential Information - MUST be completed Date installed: ... Model Description: ... Serial number: ... Company name: ...
  • Page 4: User Instructions

    Stovax offer firescreens, sparkguards and hearthgate systems for protection ‡ . Your Yeoman retailer can advise you about these products. Do not place photographs, TV’s, paintings, porcelain or other combustible items on the wall or near the appliance.
  • Page 5: Using The Appliance For The First Time

    Airwash Control CLOSE PR8721 Primary Control CLOSE DOOR OPERATION 1.14 Use a protected gloved hand to operate. DO NOT OPEN THE DOOR WITH BARE HANDS To Open and Close Rotate handle and pull door to open PR8723 WARNING Properly installed, operated and maintained this appliance will not emit fumes into the room.
  • Page 6: Lighting The Appliance

    13240: 2001 for intermittent operation: Fuel Consumption Kg/hour Description Wood Yeoman CL 3 Yeoman CL 5 Yeoman CL 8 For advice on suitable solid fuels contact your local approved coal merchant*. A number of factors can affect the performance of the appliance (see User Instructions, Section 6).
  • Page 7: Running The Appliance

    Mutli-fuel Stove Log Guard —Close the door. 5. RUNNING THE APPLIANCE Burning Wood —Close the Primary Air control and use the Airwash to control the temperature (see Diagram 8). —Wood burns best on a bed of ash (approx. 25mm (1") deep).
  • Page 8: Burning Tips

    5.12 Do not burn bituminous coal, ‘petro-coke’ or other petroleum based fuels, as this invalidates the product guarantee. Do not load fuel above the log guard and the secondary combustion inlets at the back of the firebox (see Diagram 6). 6.
  • Page 9: Ash Removal

    7. ASH REMOVAL Multi-fuel stove Riddle with the tool provided (see Diagram 9). Push/Pull to Open Door (see Diagram 10). —Using gloves carefully remove ashpan with the tool provided. Heat can remain long after use. —Place the ash into a Stovax Ash Caddy (Stovax Part No. 4227) or other suitable container.
  • Page 10: Cleaning Glass

    USER INSTRUCTIONS Check for obvious build up of soot, ash or debris above the flue baffle(s) (these can be found in the upper part of the firebox). Use a torch if necessary. If there are any signs of a build up of debris above the flue baffle(s) either: —...
  • Page 11: Troubleshooting Tips

    Do not over tighten the screws on the glass clips when replacing the glass. This causes stress and the intense temperature changes can cause the glass to crack. For replacement glass contact your local Yeoman retailer. 16.4 Appliance is producing tar This can be identified by: —...
  • Page 12: Technical Specifications

    TECHNICAL SPECIFICATION Model Yeoman CL3 - YM-CL3MF Yeoman CL5 - YM-CL5W / YM-CL5MF Yeoman CL8 - YM-CL8W / YM-CL8MF Nominal Heat Output Flue Draft at Nominal Heat Output Flue Gas Mass Flow Flue Gas Temperature at Spigot/Socket Flue Outlet Size (Top or Rear Option)
  • Page 13: Dimensions

    TECHNICAL SPECIFICATION Cast Top Plate incl. feet @ 6mm on underside Description Model Yeoman CL3 YM-CL3MF YM-CL5W Yeoman CL5 YM-CL5MF YM-CL8W Yeoman CL8 YM-CL8MF All dimensions are in mm (25.4mm = 1") YEOMAN DIMENSIONS PR8753 F (Ø) 128/5" 128/5" 153/6"...
  • Page 14: Site Requirements

    1. FLUE OR CHIMNEY The flue or chimney system must be in good condition. It must be inspected by a competent person and passed for use with the appliance before installation. Products of combustion entering the room can cause serious health risks. The following must be checked: —...
  • Page 15: Flue Exit Positions

    SITE REQUIREMENTS Position On Roof On ridge or within 600mm Elsewhere on roof On pitched, within 2300mm horizontally to openable window, dormer Within 2300mm of another building 150mm 150mm minimum 225mm minimum minimum Constructional Hearth Constructional Hearth 840mm minimum 840mm minimum 1.
  • Page 16: Walls Next To Hearth

    SITE REQUIREMENTS Solid, non-combustible material e.g. masonry or concrete 150mm minimum Position of Appliance & Hearth in relation to walls Distance of hearth from wall Distance of Appliance to wall 0 - 150mm 150mm + Suitable clearance should be allowed around the stove to enable the correct fitting and maintenance of the appliance. Any clearances should be confirmed by making a site survey and a physical check of wall thickness and dimensions.
  • Page 17: Pre-Installation

    PRE-INSTALLATION CHECKS Model Yeoman CL3 - YM-CL3MF Yeoman CL5 - YM-CL5W / YM-CL5MF Yeoman CL8 - YM-CL8W / YM-CL8MF Flue / Chimney Size Flue / Chimney minimum height* *When measured from the top of the flue, with no horizontal sections and a maximum of 4 bends with angles of less than 45°...
  • Page 18: Fitting Appliances On A Boat

    PRE-INSTALLATION CHECKS Ventilation requirements in the UK are as shown in the table below: A) Traditionally Built Homes — Where the leakage is greater than 5m — Ventilation normally required = 550mm over 5kW Output (kw) mm 2 None None Additional cm 2 None...
  • Page 19: Installation

    INSTALLATION INSTRUCTIONS LEGAL REQUIREMENTS Before installation and/or use of this appliance please read these instructions carefully to ensure that all requirements are fully understood. The appliance must be fitted by a registered installer*, or approved by your local building control officer. It is very important to understand the requirements of the national Building Regulations †...
  • Page 20: Rear Flue Installation

    INSTALLATION INSTRUCTIONS The flue must be installed in accordance with manufacturers instructions. 600mm min 1000mm max unsupported Rear flue pipe installation: —Insert a tee into the flue collar. The tee piece is used as cleaning access. —Lift appliance into position, taking care not to damage the hearth finish.
  • Page 21: Fitting & Removal Of Firebricks

    INSTALLATION INSTRUCTIONS 3. FITTING AND REMOVAL OF THE FIREBRICKS Remove the firebricks as part of the routine maintenance. This can be carried out without the use of tools. Allow the appliance to cool fully before removing firebricks. Take care when handling, as bricks can become fragile after use.
  • Page 22: Hearth Fixing

    INSTALLATION INSTRUCTIONS Main grate Remove riddling slider and connecting rod by unscrewing the 6 x M8 nuts using a 10mm A/F spanner (see Diagram Riddling slider Nuts Replace in reverse order. If the appliance is to be fixed to the hearth then use the hearth mount locking tabs shown in Diagram 10.
  • Page 23: Fitting Cast Top

    This appliance can be fitted with an optional cast top plate. The type of plate will depend on whether the appliance is installed with a top* or rear flue exit. Top Flue Yeoman CL3 YM-CL3CT Yeoman CL5 YM-CL5CT Yeoman CL8...
  • Page 24: Commissioning

    COMMISSIONING To commission: — Replace the baffle and log guard. — Check the door alignment and catch operation and adjust if required (see Maintenance & Servicing, Section 7). — Check the soundness of door seals, castings and joints. — Check the operation of the air controls. Now carry out a final smoke draw test: —...
  • Page 25: Maintenance & Servicing

    MAINTENANCE and SERVICING For a complete list of spare parts and accessories contact your Yeoman retailer or call 01392 474011 1. ANNUAL SERVICE Before the start of the heating season strip, inspect and clean the appliance as detailed: — Allow appliance to cool.
  • Page 26: Removal Of Log Guard

    During this time the appliance may give off some unpleasant odours. Keep the room well ventilated to avoid a build-up of fumes. Your Yeoman retailer can carry out service and maintenance. 2. REMOVAL OF THE LOG GUARD To remove the Log guard: —...
  • Page 27: Fitting A New Door Seal

    Do not over tighten the clamp as this could break the glass. Fit only Yeoman ceramic glass, which is suitable to use in high temperature applications. Using the appliance with damaged door glass could allow dangerous fumes to enter the room, or the appliance to over-fire and cause damage.
  • Page 28: Adjusting Door Catches & Hinges

    MAINTENANCE and SERVICING 7. ADJUSTING DOOR CATCH & HINGES To maintain the safe use of your appliance, you may need to adjust the door hinges to ensure the door closes safely and correctly. To adjust the door catch: — Open the door to gain access to the catch. —...
  • Page 29: Spares List

    YM-CL3MF Ref. Product Drawing No. Description Code (if different) CA7668 5” CAST FLUE SS13 MEC7026 5” FLUE BLANK SM15 ME7027 SECONDARY AIR COVER CE7810 FIRE BRICK CA7618 CAST PLINTH FRONT SMN37 CA7050 CENTRE GRATE SMN36 CA7049 MAIN GRATE MEC8818 ASH PAN ASSEMBLY...
  • Page 30 YM-CL5W Ref. Product Drawing No. Description Code (if different) CA7668 5” CAST FLUE 5” FLUE BLANKING PLATE SS13 MEC7026 SM15 ME7027 SECONDARY AIR COVER CE7812 BRICK RIGHT HAND CA7645 PLINTH CA7630 CLEANBURN AIR DUCT CASTING CA7664 LOG RETAINER MEC8628 DOOR ASSEMBLY S5.26 RA7239 BAFFLE...
  • Page 31 YM-CL3 Ref. Product Drawing No. Description Code (if different) CA7597 CAST DOOR MEC8619 DOOR HANDLE ASSEMBLY FA500024 WAVE SPRING - YRW-0087S17 SPRING 6.1MM O/D X 0.61MM DIAMETER WIRE FA9508 FA500016 X 22.2MM LONG FA500025 TORSION SPRING CA7635 DOOR HANDLE CAM MEC8636 HINGE PLATE ASSEMBLY ME600392...
  • Page 32: Service Records

    1ST SERVICE Date of Service:... Next Service Due:... Signed:... Retailer's Stamp/HETAS Registration Number 3RD SERVICE Date of Service:... Next Service Due:... Signed:... Retailer's Stamp/HETAS Registration Number 5TH SERVICE Date of Service:... Next Service Due:... Signed:... Retailer's Stamp/HETAS Registration Number 7TH SERVICE Date of Service:...
  • Page 34 A division of Stovax Ltd Falcon Road, Sowton Industrial Estate, Exeter, Devon, England Ex2 7LF Tel: (01392) 474500 Fax: (01392) 219932 E-mail: yeoman@stovax.com www.yeoman-stoves.co.uk...

This manual is also suitable for:

Ym-cl8mfYm-cl5mfYm-cl5wYm-cl8w