Download  Print this page

Yeoman CL MILNER BRICK YMMB Instructions For Use & Installation

Inset convector stove
Hide thumbs

Advertisement

Yeoman CL Milner Brick
Inset Convector Stove
MODELS: YMMB

Instructions for Use,

Installation and Servicing
For use in GB & IE (Great Britain and Republic of Ireland).
This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translated
instructions and in some cases the appliance will require modification. Contact Yeoman for further information.
IMPORTANT
This appliance will become hot whilst in operation, it is therefore recommended that a suitable guard should be used for the
protection of young children, the elderly or infirm. Do not attempt to burn rubbish in this appliance.
Please read these Instructions carefully before installation or use.
Keep them in a safe place for future reference and when servicing the fire.
The commissioning sheet found on page 3 of these instructions should be completed by the Installer.
PM559 - Issue 1 (June 2011)

Advertisement

Table of Contents
loading

  Related Manuals for Yeoman CL MILNER BRICK YMMB

  Summary of Contents for Yeoman CL MILNER BRICK YMMB

  • Page 1: Instructions For Use

    This appliance has been certified for use in countries other than those stated. To install this appliance in these countries, it is essential to obtain the translated instructions and in some cases the appliance will require modification. Contact Yeoman for further information.
  • Page 2: Table Of Contents

    SPARE PARTS SERVICE RECORDS EC DECLARATION OF CONFORMITY Your Yeoman retailer provides you with a Two Year Warranty for your new product. However, this specifically excludes naturally wearing parts or ‘consumables’ and the use of Some Yeoman products will also qualify for a Five Year Warranty on cast iron parts such as cast iron carcasses and cast iron doors of steel bodied stoves.
  • Page 3: Appliance Commissioning Checklist

    APPLIANCE COMMISSIONING CHECKLIST To assist us in any guarantee claim please complete the following information. In the unlikely event of a problem, contact your installer or retailer for assistance: Retailer appliance was purchased from Name: ... Address: ... Telephone number: ... Essential Information - MUST be completed Date installed: ...
  • Page 4: User Instructions

    It is found on the appliance data plate (see Diagram 1). USER INSTRUCTIONS Triple Air Systems AIR CONTROLS Several Yeoman appliances have triple air systems providing cleaner burning, and greater efficiency and control (see Diagram 2). 1) Airwash - air drawn over the window cleans the glass.
  • Page 5: Warning

    AIRWASH AND PRIMARY AIR CONTROLS SECONDARY AIR CONTROLS DOOR HANDLE 1.13 Use a protected gloved hand to operate. 1.14 Rotate clockwise and pull to open. Warning: Do not force the handle as damage may occur (see Diagram 5). DO NOT OPEN THE DOOR WITH BARE HANDS USER INSTRUCTIONS Airwash Control Open...
  • Page 6: Recommended Fuels

    3. RECOMMENDED FUELS Wood Logs: Burn only seasoned timber with a moisture content of less than 20%. To ensure this allow cut wood to dry for 12 to 18 months. Wood Length Appliance Wood Length CL Milner Brick 250mm Poor quality timber: —...
  • Page 7: Running The Appliance

    —Close the door. Do not leave the door open as this could over-fire and damage the appliance. 5. RUNNING THE APPLIANCE Burning Wood: —Close the Primary Air control and use the Airwash to control the temperature (see Diagram 9). Air Wash: Adjust —Wood burns best on a bed of ash (approx.
  • Page 8: Burning Tips

    Burn at a high temperature for a short period each day to avoid large build-ups of tars and creosotes within the appliance and the flue system. Use Yeoman Protector chimney cleaner to reduce this problem. Fuel Quality (Solid Fuel) Use recommended solid fuels approved for use with closed appliances.
  • Page 9: Ash Removal

    —Open doors and using gloves remove ashpan with the tool provided (see Diagram 10). —Remove ash and place into a Yeoman Ash Caddy (Yeoman Part No. 4227) or other suitable container. Do not place hot ash in any container made from plastic or any other combustible material.
  • Page 10: General Cleaning

    14. CARE OF STOVE Yeoman has a range of cleaning and maintenance products and accessories to keep your appliance in good working order. Your Yeoman retailer can advise you on suitable items for your stove and provide genuine spare parts such as replacement glass, door sealing rope and firebricks.
  • Page 11: Seasonal Use

    Do not over tighten the screws on the glass clamp when replacing the glass. This causes stress and the intense temperature changes can cause the glass to crack. For replacement glass contact your local Yeoman retailer. 16.4 Appliance is producing tar This can be identified by: —...
  • Page 12: Technical Specification

    TECHNICAL SPECIFICATION Model CL Milner Brick Nominal Heat Output Flue Draught at Nominal Heat Output Flue Gas Mass Flow Flue Gas Temperature Flue Outlet Size Weight Recommended Fuels Do not burn petroleum based fuels such as petro-coke, as these will seriously damage the appliance. As tested to the requirements of EN 13229 for intermittent operation.
  • Page 13: Dimensions

    SITE REQUIREMENTS CL INSET DIMENSIONS PR9036...
  • Page 14: Site Requirements

    SITE REQUIREMENTS 1. FLUE OR CHIMNEY The flue or chimney system must be in good condition. It must be inspected by a competent person and passed for use with the appliance before installation. Products of combustion entering the room can cause serious health risks.
  • Page 15: Flue Outlet Positions

    SITE REQUIREMENTS These positions are defined by Document J of the Building Regulations. Point where the flue passes through weather surface (Notes 1 &2) At or within 600mm of the ridge Elsewhere on roof (whether pitched or flat) Below (on a pitched roof) or within 2300mm horizontally to openable rooflight, dormer window, or other opening (Note 3) Within 2300mm of an adjoining or adjacent building, whether or not beyond the boundary (Note 3)
  • Page 16: Milner Brick Opening

    If the appliance is to be fitted with a fire surround, use the minimum clearances shown in the diagram below between any point of the appliance and any combustible material. Yeoman produce a selection of surrounds and details can be obtained from your local supplier. PR8850...
  • Page 17: Pre-Installation

    — Purpose provided ventilation. — Some Yeoman appliances can also be fitted with an optional outdoor air kit which allows air to be drawn in from the outside. The amount of air required must comply with local building regulations and the rules in force.
  • Page 18: Fitting Appliances On A Boat

    PRE-INSTALLATION CHECKS 2.11 Extractor fans or cooker hoods must not be placed in the same room or space as this can cause the appliance to emit fumes into the room. 2.12 Increase air supply provisions where a room contains multiple appliances.
  • Page 19: Installation Instructions

    INSTALLATION INSTRUCTIONS LEGAL REQUIREMENTS Before installation and/or use of this appliance please read these instructions carefully to ensure that all requirements are fully understood. The appliance must be fitted by a registered installer approved by your local building control officer. It is very important to understand the requirements of the national and standards ‡...
  • Page 20: Removal Of Door

    INSTALLATION INSTRUCTIONS Reposition clamps by hand through the flue opening and tighten using a 13A/F spanner. Check the clamps are against the throat forming lintel as shown in Diagram 3. ø 16mm Rope seal Clamp Reach through door and up and out of flue opening to adjust clamps Check the ø16mm rope seal is still in the correct position.
  • Page 21: Fitting & Removal Of Grate

    INSTALLATION INSTRUCTIONS To remove the baffle: — Open door. — Lift the front edge of the baffle to clear the support bars. — Pull the baffle forward to disengage the rear edge from the location above the secondary air inlet holes. —...
  • Page 22: Fitting & Removal Of Cleanburn Chamber

    Lift chamber, rotate forward and remove from stove. Check rope seal is in good condition (see Diagram 11). If necessary, replace using Yeoman 10 x 2 insulation tape (Yeoman Part No. 4953). 7. REMOVAL OF CAST IRON FIREBRICKS Allow the appliance to cool fully before removing firebricks.
  • Page 23: Commissioning

    COMMISSIONING To commission: —Replace the baffle and log guard. —Check the door alignment and catch operation and adjust if required (see Maintenance & Servicing, Section 8). —Check the soundness of door seals, castings and joints. —Check seal of the stove to the wall. —Check the operation of the air controls.
  • Page 24: Maintenance & Servicing

    MAINTENANCE and SERVICING For a complete list of spare parts and accessories contact your Yeoman retailer or call 01392 474011 1. ANNUAL SERVICE Before the start of the heating season strip, inspect and clean the appliance as detailed: — Allow appliance to cool.
  • Page 25: Removal Of Log Guard

    MAINTENANCE and SERVICING 2. REMOVAL OF THE LOG GUARD To remove the log guard: — Lift log guard clear of the supporting brackets. — Rotate to clear the sides of the door opening. Do not use appliance without the log guard in position. 3.
  • Page 26: Fitting A New Door Seal

    Maintenance & Servicing Section 8, Page 27. Do not over tighten the clamp as this could break the glass. Fit only Yeoman ceramic glass, which is suitable to use in high temperature applications. Using the appliance with damaged door glass could allow dangerous fumes to enter the room, or the appliance to over-fire and cause damage.
  • Page 27: Adjusting The Door Catch

    MAINTENANCE and SERVICING 8. ADJUSTING DOOR CATCH & HINGES To maintain the safe use of your appliance, you may need to adjust the door hinges to ensure the door closes safely and correctly. To adjust the door hinge plate assembly: —...
  • Page 28: Spare Parts

    Ref. Product Drawing No. Description Code (if different) CA7660 CANOPY ME600486 MESH STMB-MEC8609 MEC8609 AIR WASH DUCT ASSEMBLY CLAMP RA502311 M08200STUD M08 x 200 STUD RA502305 BAFFLE ME600493 CATCH CLAMP ME600521 LATCH SCREW RA502310 SECONDARY AIR CONTROL SPACER ME600395 MEC8617 ASH PAN ASSEMBLY CA7662 MAIN GRATE...
  • Page 29 Ref. Product Drawing No. Description Code (if different) CA7638 OUTER DOOR MEC600455 DOOR HANDLE STOP RING MEC8619 DOOR HANDLE ASSEMBLY FA500025 TORSION SPRING SPRING 6.1 O/D X 0.61 DIA WIRE X 22.2 LG FA9508 FA500016 CA7635 DOOR HANDLE CAM MEC8636 HINGE PLATE ASSEMBLY CE7732 DOOR GLASS...
  • Page 30: Service Records

    1ST SERVICE Date of Service:... Next Service Due:... Signed:... Retailer's Stamp/HETAS Registration Number 3RD SERVICE Date of Service:... Next Service Due:... Signed:... Retailer's Stamp/HETAS Registration Number 5TH SERVICE Date of Service:... Next Service Due:... Signed:... Retailer's Stamp/HETAS Registration Number 7TH SERVICE Date of Service:...
  • Page 32 A division of Stovax Stovax Ltd, Falcon Road, Sowton Industrial Estate, Exeter, Devon, England EX2 7LF Tel: (01392) 474011 Fax: (01392) 219932 E-mail: info@stovax.com www.stovax.com...