tousek TPS 60 PRO m6 Mounting And Installation Manual

tousek TPS 60 PRO m6 Mounting And Installation Manual

Sliding gate operator
Table of Contents

Advertisement

Quick Links

Mounting and installation manual
Sliding gate operator TPS 60 PRO m6
Safety Sensor

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TPS 60 PRO m6 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for tousek TPS 60 PRO m6

  • Page 1 Mounting and installation manual Sliding gate operator TPS 60 PRO m6 Safety Sensor...
  • Page 2: Table Of Contents

    Dimensioned drawings TPS 60 PRO ......................33 This manual is the sole property of the TOUSEK Ges.m.b.H. and may not be made available to competitors. All rights reserved. No part of it may be reproduced without our prior written permission. We will not accept liability for any claims resulting from misprints or errors. This edition of the manual replaces all earlier publications of the same.
  • Page 3: General Warning And Safety Notes

    EU and in the individual countries have to be strictly followed. • The TOUSEK Ges.m.b.H. cannot be held liable for any claims resulting from disregards of the laws and standards in force during the installation and operation.
  • Page 4: General Product Features, Function, Technical Data Tps 60 Pro

    Gates on sloping tracks (i.e. gates which follow an inclined, non-horizontal, travel path) must not be automated without additional safety devices (which make sure that the gate cannot start moving on its own from any gate position). - 4 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 5: Installation

    193 ± 20mm General installation notes Before installing the Tousek TPS 60 PRO sliding gate operator we recommend checking the following points: • Checking the gate structure: On a gate which travels on floor rails please check the bottom rollers and the upper guide rollers and make sure that there is no undue friction or jamming.
  • Page 6: Mounting Of The Motor

    • In case that special regulations require another type of cable, cables according to these regulations have to be used. Mounting dimensions TPS 60 PRO (in mm) Ground plate (1a) Cable inlet (1b) Slotted holes (4x) Gear wheel Z17m6 Steel gear rack m6 mounting angle Z17m6 - 6 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 7: Mounting The Fork For The Power Supply System (Optional)

    • Thereafter, push the screw piece (S) into the rail that runs along the brush inside the housing, and screw the fork sup- port (10b) by means of two hexagon socket screws. - 7 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 8: Mounting Of The Gear Rack

    1 mm between the flank of the drive pinion and the gear rack. • After that fix the angles again with the bolts (M). Attention Do not weld the individual gear rack elements together! - 8 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 9: Limit Switches And Emergency-Stop Button

    2.5 Dismantling The dismantling of motor is made the other way around of mounting. Before dismantling plug off power supply of motor ! - 9 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 10: Control Box

    3 Measure the voltage supply of DC-Busses between clamps PA/+ and PCI-, to make sure that the voltage is under 42 Vd.c. 4 Should the DC-Bus-condensers not fully discharge please contact manufacturer. The converter should not be used or repaired in such a case. - 10 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 11: Layout Of The Contro Box

    (TSI) Terminal block Connection frequency converter 230V Schuko socket Connection torque sensor Limit switch module Slot for optional I-loop detector Bussystem module limit switch/control board Slot for optional radio receiver - 11 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 12: Limit Switch Module

    - Terminal block X1: S1/S1 input EMERGENCY- switch 2 x Magnets to trigger the reed limit switches 2 x Emergency trigger to trigger the emergency stop switch pre-wired Limit switch module - 12 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 13: Clamp/Terminal Assignment To Terminal Block X1

    The stop input has no emergency stop function! - In order to ensure the emergency stop function, provide the supply line with an all-pole disconnecting emergency stop switch, that locks after actuation! - 13 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 14: Settings - Overview, Programming Buttons, Program Menu, Basic Setting

    The different menu points are indicated as follows:  = selectable settings  = factory settings  = status display shows the menu points which are in the “ BASIC SETTINGS” - 14 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 15: Menu Structure

    Note: Some changes regarding mode of operation and operation logic will only be accepted if the gate is closed and „eady to use“ appears on the display. ENTER sliding gate opener TPS 60 PRO control board for - 15 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 16: 3.5 Connections And Adjustments

    Select only after putting into operation (see page 28), if desired. As impulse emitters pushbuttons or key switches as well as external radio receivers with potential free make contacts can be used - 16 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 17: Pedestrian Switch (Terminals X1: 30/34)

    The stop input has no emergency stop function! - In order to ensure the emergency stop function, provide the supply line with an all-pole disconnecting emergency stop switch, that locks after actuation! - 17 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 18: Safety

    • You will find detailed information in the corresponding photocell manual. Photocells (contact: terminals X1: 46/47) Safety  ACTIVE: to be selected, if photocell should be triggered.  NOT ACTIVE to be selected, if photocell should not be triggered. - 18 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 19: Photocell - Connection Examples

    12/24V 1 2 3 4 5 receiver 2 transmitter 2 Important • as the LS 45/2 has no SYNC-function, both photocell transmitters and receivers must be mounted on different sides! - 19 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 20: G Main Clos. Edge (Terminals X1: 50/52)

     Stop during closing , then close : an interruption of the photocell during closing movement makes the motor stop as long as the photocell stays interrupted. After release of the photocell, the gate closes. - 20 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 21: Photocell With Pause Time

     0...-30 adjustable [increments in 1 steps] : This setting is only accepted in the close position. ATTENTION: For the adjustments the valid safety regulations and standards have to be strictly followed ! - 21 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 22: Operating Logic

    With this function e.g. the entrance to a company site can remain open during the day (1st impulse in gate open position) and closed in the evening (2nd impulse). The control board switches back to automatic mode (autom. opening and closing of gate) - 22 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 23: Lamps / Lights

    If the gate is closed, – (24V, max. 2W) the pilot lamp expires  Illuminated when gate is open: Pilot lamp is illuminated as soon as the gate has reached end position open - 23 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 24: Diagnosis

    DAYS HOURS : MINUTES : SECONDS $$$$$$$$$$$$$$$$ T -00 00:00:00.0 $$$$$$$$$$$$$$$$ event Type of event Status Sensor Reset / Diagnose  Degree and signal strenght of rotation speed sensor is shown on display. - 24 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 25: Other Connections Of Tps 60 Pro

    “permanent open” switch input. To evaluate the I-loops, you need the optional detector I-loop 2 ISD 6 (see page 26). I-loop 1 For more information see manual ISD 6. - 25 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 26: I-Loop Detector (Optional)

    • Reset: average duration of the key press (> 2s), reset the detector, subsequent initialization of all channels. Insert the board of the induction loop detector on the slot (ISD) of the control board. - 26 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 27: Connection Of Radio Receiver

    • For programming of receiver please see manual for into the corresponding slot (FE) as shown in the picture. radio receiver. • To increase the range an external antenna FK433 or FK868 can be connected. - 27 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 28: Commissioning

    • The next programming adjustments are made in the main settings menu (see page 14, 15). Factory settings change? YES $$$$$$$$$$$$$$$$ Photocell $$$$$$$$$$$$$$$$ Photocell $$$$$$$$$$$$$$$$ $$$$$$$$$$$$$$$$ active confirm $$$$$$$$$$$$$$$$ Photocell $$$$$$$$$$$$$$$$ not active - 28 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 29 (with „-“ button): Radio edge TX  TX 400  change? YES $$$$$$$$$$$$$$$$ Opening direct. $$$$$$$$$$$$$$$$ Opening direct. $$$$$$$$$$$$$$$$ $$$$$$$$$$$$$$$$ <<<--- left confirm $$$$$$$$$$$$$$$$ Opening direct. $$$$$$$$$$$$$$$$ --->>> right - 29 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 30: Emergency Release In Case Of Power Failure (Note For The User)

    Ther image shows a motor in “locked” position. By giving the next impulse, the actuator looks for its open position (it is not necessary to re-programm the end positions). - 30 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 31: Error Diagnosis

    It is essential to instruct children about the risks. The TOUSEK Ges.m.b.H. rejects any liability if the product is used in any way not fully conforming to its original purpose as stated herein.
  • Page 32: Cable Plan

    - 32 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 33: Dimensioned Drawings Tps 60 Pro

    (4) Openings for height-adjustable fork for the power supply system (5) EMERGENCY spring bar switch Z17m6 We reserve the right to change dimensions and technical specifications without prior notice. - 33 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 34 Event log Loading parameters The last 1000 cycles (approx.) are saved with indication of Load your settings day and time. onto the control Sortable by different boards or readout events. parameters. - 34 - tousek / EN_TPS-60-PRO_05 / 25. 03. 2020...
  • Page 35 Date/ Signature response to a duly substantiated request. TOUSEK Ges.m.b.H., A1230 Wien, Zetschegasse 1, Austria is authorized to compile the technical documentation. The incomplete machine cannot be put into service, until it...
  • Page 36 Buitenheide 2A/ 1 Tel. +32/ 11/ 91 61 60 your service partner: Fax +32/ 11/ 96 87 05 info@tousek.be Tousek Sp. z o.o. Poland PL 43-190 Mikołów (k/Katowic) Gliwicka 67 Tel. +48/ 32/ 738 53 65 Fax +48/ 32/ 738 53 66 info@tousek.pl...