Specifications; Drive Specifications - Emerson Control Techniques EN Series Installation Manual

Hide thumbs Also See for Control Techniques EN Series:
Table of Contents

Advertisement

Drive Specifications

Power Requirements
Switching Frequency
Logic Supply
Auxiliary Power Supply/
Auxiliary Logic Power Input
Encoder Supply Output
Efficiency
Regeneration
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
EN Drive Installation Manual
EN Drive Specifications
90 - 264 VAC, 47-63 Hz
(240 VAC for rated performance)
EN-204: 1Ø
AC Input Voltage:
EN-208: 1Ø
EN-214: 3Ø (for 1Ø operation, drive output power
must be derated by 20%)
EN-204: 9.5 Arms (140A for 8ms inrush)
EN-208: 19 Arms (140A for 8ms inrush)
AC Input Current:
EN-214: 20 Arms 1Ø (140A for 5ms inrush)
EN-214: 14 Arms 3Ø (100A for 5ms inrush)
EN-204: 4.5 Arms
Output Continuous Current
EN-208: 9 Arms
(RMS):
EN-214: 13 Arms (for 1Ø, derate by 20%)
EN-204: 9 A
EN-208: 18 A
Output Peak Current:
EN-214: 26 A (for 1Ø, derate by 20%)
EN-204: 1.8 kW
EN-208: 3.6 kW
Continuous Output Power:
EN-214: 5.2 kW
20 kHz
Internal
127 - 373 VDC, 22 W
+5 VDC, 250 mA
93%
EN-204: 79 Joules
Internal Energy Absorption
EN-208: 50W Resistor plus 79 Joules
(230V):
EN-214: 50W Resistor plus 79 Joules
EN-204: 150 Joules
Internal Energy Absorption
EN-208: 50W Resistor plus 150 Joules
(115V):
EN-214: 50W Resistor plus 150 Joules
Connection to RSR-2 with external resistor, 20 Ohms
External:
min, 15 Arms, 2 kW

Specifications

47