Hardware Preparation and Installation
2.1
Environmental and Power Requirements
You must make sure that the board, when operated in your particular system configuration,
meets the environmental requirements specified below.
Operating temperatures refer to the temperature of the air circulating around the board and
not to the component temperature.
Product Damage
High humidity and condensation on surfaces cause short circuits.
Do not operate the system outside the specified environmental limits. Make sure the
product is completely dry and there is no moisture on any surface before applying
power.
2.1.1
Environmental Requirements
Table 2-1 Environmental Requirements
Environmental Factor
Temperature
Shock
Vibration
Air Flow
Humidity
COMX-CAR-610 COM Express Carrier Board Installation and Use (6806800K26D)
Operating
0 to +55°C
20 g 11 ms sine or saw
0.01g ^2/Hz at 5-500 Hz Random
Vibration
400 LFM at 0 to 55°C
10-90% (non-condensing)
Chapter 2
Non-Operating
-40 to +85°C
21