Electrical Hookup - Honeywell F116 Series Product Data

2 self-contained ductable commercial air cleaner
Hide thumbs Also See for F116 Series:
Table of Contents

Advertisement

Electrical Hookup

All wiring must comply with applicable codes and
ordinances. The power source must agree with the model
type: 120V, 60 Hz. Refer to figure 16 for electrical
connection setup.
1. Remove screws on motor compartment cover and
remove.
2. Refer to figure 16 for typical electrical diagram
WARNING
Risk of Fire or Electric Shock.
Can cause personal injury or equipment damage.
Use only Honeywell 190097C Remote Speed
Switch (3-speed models only) to regulate air
cleaner speed. Using a different speed switch may
void the warranty.
IMPORTANT
• Be sure the air cleaner is grounded for correct
operation and safety.
• Canadian installation: NEVER install in ceilings
with thermal insulation value greater than R-40.
FACTORY WIRING
BLACK
BROWN
EXTERNAL
WIRING BY
INSTALLER
WHITE
GREEN
Fig. 16. Typical F116 Series 2 only 120V, 60 Hz wiring
diagram.
Remote 3 Speed Wall Switch
(F116 Series 2)
The 190097C Remote Wall Switch Assembly allows
control of the F111 model air cleaners from a a location
separate from the air cleaner. The assembly includes a
remote switch with an outlet box cover, outlet box,
extension ring, and a wire harness. Wiring to connect the
remote switch and air cleaner must be furnished
separately.
CAUTION
• This installation to be performed only by a
qualified installer.
• All wiring to comply with local electrical codes.
• Disconnect power to air cleaner at fuse or breaker
before beginning work. Failure to do so can result
in shock hazard endangering equipment and
personal safety of installer.
• Only one air cleaner can be connected to a remote
switch
1. Disconnect power to air cleaner.
2. Mount 4" x 4" outlet box at desired remote location.
F116 SERIES 2 SELF-CONTAINED DUCTABLE COMMERCIAL AIR CLEANER
BLACK
RED
BLUE
MOTOR
VIOLET
A100002
3. Attach 3/4" extension ring to outlet box.
4. Run five conductor, color-coded, 14-gauge wires
from the remote switch location to the air cleaner.
5. Use three wire nuts to connect three color-coded,
lead wires on the remote switch to three color-coded
wires from the air cleaner. (Red, Blue, Violet)
6. Use one wire nut to connect white color-coded, lead
wire from the air cleaner to single color-coded wire
from the power supply. (White)
A100001
Fig. 17. Wiring 3-Speed Remote Switch
7. Connect the ground wire from the power supply to a
ground stud of the outlet box.(Green)
8. Connect the ground wire from the air cleaner to the
ground stud of the outlet box.(Green)
9. Use one wire nut to connect the black color-coded,
lead wire on the remote switch to the black color-
coded wire from the power supply.
10. Fold wires into box and mount remote switch on out-
let box. Leave switch in OFF position.
11. On the air cleaner remove two screws on wiring com-
partment cover and open
12. Run five conductor, color coded, 14 gauge wires
from the remote switch through the air cleaner
access opening into the wiring compartment. Strip
ends of remote switch lead wires
13. Connect three wires on air cleaner to remote switch
lead wires with wire nuts following color code used at
remote switch. (Red, Blue, Violet)
14. Connect one wire on air cleaner to power supply wire
with a wire nut following color code used at remote
switch. (White)
15. Connect the ground wire from the remote switch to a
ground stud of the wiring compartment
cover.(Green)
16. Fold wires into wiring compartment. Replace wiring
compartment cover.
17. Turn on power to air cleaner at fuse or breaker.
18. Check operation by turning air cleaner at HIGH,
MEDIUM, and LOW. Note that only the remote
switch will operate the air cleaner.
19. Turn off the power and install the filters in the cabi-
net.
NOTE: Select models have a disposable aluminum
spacer. the spacer is necessary only when using
the CPZ modules. All other filters need to remove
and save the spacer for future needs. Refer to fig-
ures 1 and 2.
11
BLACK
68-0200—07

Advertisement

Table of Contents
loading

This manual is also suitable for:

F116a1021-3sF116c1112-3sF116c1173-3s