Battery - Yamaha EF3000iSE, EF3000iSEB Owner's Manual

Yamaha generator owner's manual
Hide thumbs Also See for EF3000iSE, EF3000iSEB:
Table of Contents

Advertisement

q
q
e
e
r
q
w
EF3000iSEB
to STARTER RELAY
to DC-DC
CONVERTER
AE01083

BATTERY

(See page 30)
w
q
Installation
q
1. Loosen the bolts 1 and remove the cover 2.
788-006
2. Loosen the bolts 3 and remove the battery box 4.
e
e
788-007
3. Remove the band 5 to remove the battery 6.
t
4. Fill the battery with the electrolyte.
y
762-044
5. Turn the engine switch to the "STOP" position to
e
6. Install the battery onto the battery box.
7. Connect the positive lead 1 to the positive battery
r
762-045
NOTE:
9 Clamp the red wire to the positive (+) terminal first,
to ENGINE
9 For EF3000iSEB, tighten the two positive battery
762-045a
Refer to the instruction sheet included with the
electrolyte for filling instructions.
prevent accidental short circuiting.
terminal 2, then the negative lead 3 to the nega-
tive battery terminal 4.
then the black wire to the negative (-) terminal of
the battery. Do not reverse these positions.
leads (one from the starter relay and one from the
DC-DC converter) to the same positive terminal
and the two negative battery leads (one from the
engine and one from the DC-DC converter) to the
same negative terminal.
– 13 –

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ef3000iseEf3000isebEf3000isEf6300isde

Table of Contents