Display Messages

The [ERROR] and [PEAK] indicators on the front panel of the DME Satellite indicate error and warning messages.

Error Messages

Indicator
Lit
Lit
Lit
Lit
Lit
Lit
Lit
Lit

Warning Messages

Flashing
rapidly
Flashing
slow
38
DME8i-ES/DME8o-ES/DME4io-ES Owner's Manual
A system error has occurred.
Flashing
Data inside the internal flash
Flashing
memory has been erased.
The internal battery is
Flashing
completely discharged or not
installed.
A scene recall attempt has
Flashing
failed.
Audio is not input or output and
is muted due to insufficient DSP
resources.
Flashing
The network is not
communicating properly.
Flashing
Duplicate IP addresses.
Flashing
The DME Satellite contains data
for a different device group or
no data.
Flashing
Indicator
The internal battery is almost
discharged. Your data may be
lost.
The backup battery voltage is
low.
Error
Execute the "Initialize DME" operation, then restart it. If the error
indicators are still indicating the error, execute the "Delete All Data"
initialization. If the problem persists, contact a Yamaha dealer.
The firmware update operation may have failed. Use DME Designer
to execute the Recovery update operation. If the problem persists,
contact a Yamaha dealer.
If you turn off the power to the unit, the current settings will be lost
and reset to the default values. Stop operating the unit, and contact a
Yamaha dealer regarding battery replacement.
Use DME Designer to recall the scene again.
If the problem persists, contact a Yamaha dealer.
This error sometimes occurs if you try to operate a configuration at 96
kHz that has been created with a word clock of 48 kHz. To operate a
configuration at any word clock setting, use DME Designer to create
a configuration with the word clock set to 96 kHz.
Connect the Ethernet cables properly, and make sure that the
network devices are operating correctly.
Connect your computer to the DME Satellite via USB, then set a
unique IP address.
Send data appropriate for the actual device configuration from DME
Designer.
Error
If you turn off the power to the unit, the current settings may
be lost and reset to the default values. Stop operating the
unit, and contact a Yamaha dealer regarding battery
replacement.
This does not affect the operation of the unit. However, if you
continue using the unit, the settings may be lost and reset to
the default values. Contact a Yamaha dealer regarding
battery replacement at your earliest convenience.
Action
Action