Yamaha PM5D User Manual page 376

Digital mixing console/digital mixing system
Hide thumbs Also See for PM5D:
Table of Contents

Advertisement

Formato dati MIDI
4.10 Level Meter Data – Parameter change –
4.10.1 Format
Once a Level Meter Request is received to enable transmission, the specified
meter data will be transmitted at 50 msec intervals for a duration of ten seconds.
If you want meter data to be transmitted continuously, you must transmit a
Request at intervals of no longer than ten seconds.
Reception
This message is echoed if [Parameter change ECHO] is ON.
Transmission
Once transmission is enabled by a Request, the meter data specified in the
Address will be transmitted on the [Rx CH] channel at a specific interval for a
specific duration. (The transmission interval and the duration of transmission
will differ between models of device.)
Transmission is disabled when the power is cycled, or when PORT settings are
changed.
If [Parameter change ECHO] is ON, the message is transmitted without change.
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0001nnnn 1n
GROUP ID
00111110 3E
MODEL ID
00001111 0F
DATA
00100001 21
CATEGORY
DATA
0mmmmmmm mm
0mmmmmmm mm
0mmmmmmm mm
0ddddddd dd
0ddddddd dd
:
:
EOX
11110111 F7
4.10.2 Format
Reception
This message is received if [Parameter change RX] is ON and [Rx CH] matches
the Device number included in the SUB STATUS. This message is echoed if
[Parameter change ECHO] is ON.
When this is received, the meter data specified in the Address is transmitted on
the [Rx CH] channel at a specific interval for a specific duration.
If this is received with an Address UL = 0x7F, transmission of all meter data will
stop (will be disabled) immediately.
Transmission
If [Parameter change ECHO] is ON, the message is transmitted without change.
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0011nnnn 3n
GROUP ID
00111110 3E
MODEL ID
00001111 0F
DATA
00100001 21
CATEGORY
DATA
0mmmmmmm mm
0mmmmmmm mm
0mmmmmmm mm
0ccccccc ch
0ccccccc cl
EOX
11110111 F7
376
PM5D/PM5D-RH V2/DSP5D – Manuale di istruzioni
(Parameter change)
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
Digital mixer
PM5D
REMOTE LEVEL METER
ADDRESS UL
ADDRESS LU
ADDRESS LL
Data1 H
Data1 L
End of exclusive
(Parameter request)
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
Digital mixer
PM5D
REMOTE LEVEL METER
ADDRESS UL
ADDRESS LU
ADDRESS LL
Request Ch Total Number H
Request Ch Total Number L
End of exclusive
4.11 Time Counter Data – Time Code –
4.11.1 Format
When transmission is enabled by receiving a Remote Time Counter request,
Time Counter data is transmitted at 50 ms intervals for a duration of ten
seconds. If you want counter data to be transmitted continuously, you must
transmit a Request at intervals of no longer than ten seconds.
Reception
This message is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission is enabled by a request, Time Counter data is transmitted
for a specific duration.
Transmission is disabled when the power is cycled, or when PORT settings are
changed.
If [Parameter change ECHO] is ON, the message is transmitted without change.
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0001nnnn 1n
GROUP ID
00111110 3E
MODEL ID
00001111 0F
DATA
00101011 2b
CATEGORY
DATA
0ddddddd dd
0ddddddd dd
0ddddddd dd
0ddddddd dd
EOX
11110111 F7
4.11.2 Format
Reception
This message is received if [Parameter change RX] is ON and [Rx CH] matches
the Device number included in the SUB STATUS. This message is echoed if
[Parameter change ECHO] is ON.
When this message is received, Time Counter data is transmitted on the [Rx
CH] channel for a specific duration.
If a message is received with 0x7F as the second byte of the Address, data
transmission will be stopped (disabled) immediately.
Transmission
If [Parameter change ECHO] is ON, the message is transmitted without change.
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0011nnnn 3n
GROUP ID
00111110 3E
MODEL ID
00001111 0F
DATA
00101011 2b
CATEGORY
DATA
0ddddddd dd
EOX
11110111 F7
Sezione riferimenti
(Parameter change)
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
Digital mixer
PM5D
Time Counter TC
Hour
Minute
Second
Frame
End of exclusive
(Parameter request)
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
Digital mixer
PM5D
Time Counter TC
0: Request transmission
0x7F: Request stop transmission
End of exclusive

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pm5d-rhDsp5dPm5d-rh v2

Table of Contents