Installation Requirements; Tools And Parts; Location Requirements - Whirlpool WVW91330KS Installation Instructions And Use & Care Manual

Wall-mount canopy range hood
Table of Contents

Advertisement

Available languages

Available languages

Tools and Parts

Gather the required tools and parts before starting installation.
Read and follow the instructions provided with any tools listed
here.
Tools Needed
Level
Drill with 1¼" (3.0 cm), 3/8" (9.5 mm), and 5/16" (7.9 mm)
drill bits
Pencil
Wire stripper or utility knife
Tape measure or ruler
Pliers
Caulking gun and weatherproof caulking compound
Vent clamps
Jigsaw or keyhole saw
Flat-blade screwdriver
Metal snips
Phillips screwdriver
Parts needed
Home power supply cable
1/2" (1.3 cm) UL listed or CSA approved strain relief
3 UL listed wire connectors
For vented installations, you will also need:
1 wall or roof cap
Metal vent system
For non-vented (recirculating) installations, you will also
need:
Recirculation Kit - See "Assistance or Service" section to
order.
6" (15.2 cm) dia. round metal vent duct - length required is
determined by ceiling height.
Parts Supplied
Remove parts from packages. Check that all parts are included.
Hood canopy assembly with blower, light bulbs, and canopy
glass already installed
Vent transition with back draft dampers installed
Metal grease filter
Vent cover support bracket
Mounting template
2-piece vent cover
Air deflector (for non-vented [recirculating] installations only)
2 - 3.5 x 9.5 mm T10 screws
4 - 4.2 x 8 mm T20
screws
®
6 - 5 x 45 mm mounting screws (for 8 x 40 mm wall anchors)
2 - 8 x 40 mm wall anchors
4 - 10 x 60 mm wall anchors
4 - 5.4 x 75 mm screws (for 10 x 60 mm wall anchors)
T10 Torx
adapter
®†
T20
Torx
adapter.
®†
®
TORX and T20 are trademarks of Acument Intellectual Properties, LLC.
®
4

INSTALLATION REQUIREMENTS

Location Requirements

IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the
installer's responsibility to comply with installation clearances
specified on the model/serial/rating plate. The model/serial/
rating plate is located behind the left filter on the rear wall of the
vent hood.
Canopy hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used.
Given dimensions provide minimum clearance.
Grounded electrical outlet is required. See "Electrical
Requirements" section.
The canopy hood is factory set for venting through the roof or
wall. For non-vented (recirculating) Installation see "For non-
vented (recirculating) installation only" in the "Connect Vent
System" section. Recirculation Kit Part Number W10294733 is
available from your dealer or an authorized parts distributor. All
openings in ceiling and wall where canopy hood will be installed
must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the
Manufactured Home Construction Safety Standards, Title
24 CFR, Part 328 (formerly the Federal Standard for Mobile
Home Construction and Safety, Title 24, HUD, Part 280) or when
such standard is not applicable, the standard for Manufactured
Home Installation 1982 (Manufactured Home Sites, Communities
and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with
local codes.
Product Dimensions
10⁷⁄₈"
4⁷⁄₈"
(27.6 cm)
(12.3 cm)
13³⁄₁₆"
(33.5 cm)
30" (76.2 cm) or
36" (91.4 cm)
*For non-vented (recirculating) installations
**For vented installations
5¹⁵⁄₁₆"
(15.0 cm)
*27⁵⁄₁₆" (69.4 cm) min.
45¹⁵⁄₁₆" (116.6 cm) max.
21"
(53.3 cm)
14³⁄₄"
**27⁵⁄₁₆" (69.4 cm) min.
(37.6 cm)
42" (106.7 cm) max.
1¹³⁄₁₆"
(4.6 cm)
19¹¹⁄₁₆" (50.0 cm)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Wvw91336ks25104982701685

Table of Contents