Fault Finding - VB RONDA F-501 User Manual

For collection of a large amount of dust
Table of Contents

Advertisement

Available languages

Available languages

RONDA
F-501
®
Remember:
Has the machine been used for dust hazardous to health you MUST wear personal protection equipment
(PPE) when emptying and handling the machine.
Always empty the machine after use.
Cleaning and maintenance
Always empty the machine after use. If the unit is left with collected material for a longer time – there is a risk for
self-ignition (depending on material)
 Clean the outside of the pre-separator with a dry or moist cloth.

Fault finding

If the pre-separator is not delivering full suction:
The suction hose, tube or nozzle may be blocked.
Stop the machine, and remove the blocking.
The collection container or the collection bag may be filled to overflowing.
Stop the machine and empty the container. See the chapter about emptying.
A leak might have arisen in connection with the mounting of the top.
Start the machine and block the suction hose. Normally you can hear a possible leak.
The collection bag is sucked up.
The valve not open. Open the valve.
A leak in the system. Check the system for leaks.
RONDA
F-501
19