  • Page 1 TRANSITION CMY Fiber Optic Illuminator CMY with TW -White light with WT -White light Transition User Manual...
  • Page 2: Table Of Contents

    Table of Contents Declaration of Conformity………………………………………………..3 Safety Notice………………………………………………………………4 Introduction to Transition…………………………………………………7 Transition Quick Start configuration…………………………………….8 Transition Specifications…………………………………………………9 Fixture Setup and Configuration……………………………………..…10 DMX / RDM Setup and Operation……………………………………...12 Display Messages………………………………………………………..13 Service…………………………………………………………………….15 Flash Reprogramming…………………………………………………...17 Warranty Information……………………………………………………..18 Figure 2.1 Figure 1.2………………………………………………….….19...
  • Page 4: Safety Notice

     Use in a dry location only. Product Modification Warning Wybron, Inc. products are designed and manufactured to meet the requirements of United States and International safety standards. Modifications to the products could affect safety and render the product non-compliant to relevant safety standards.
  • Page 6 Intro to the Transition...
  • Page 7: Introduction To Transition

    Transition Product Introduction Wybron is pleased to announce the introduction of the Transition fiber illuminator. Contained within a small easy to integrate package and ultra bright fiber optic illuminator, the Transition brings quality and durability to your venue. In addition, the Transition is designed to be an integral component of Wybron’s industry...
  • Page 8: Transition Quick Start Configuration

    Transition Quick Start Configuration 1. Connect the Equipment a) Connect fiber bundle common end to the Transition output port. b) Connect the Transition to a DMX source with a 5-pin cable c) Connect to AC power (110 – 240 VAC 50/60Hz) 2.
  • Page 9: Transition Specifications

     No lamp optimization required  Rubber feet for cabinet or countertop installation  Durable all metal construction  Output supports fiber bundles ranging from 17 – 30 mm dia.  High output 150W UHI compact arc source  Legendary Wybron Reliability...
  • Page 10: Fixture Setup And Configuration

    Fixture Setup and Configuration Installing the Lamp DANGER: Disconnect fixture from line voltage before replacing lamp. CAUTION: Lamp and lamp mounting surfaces are hot! Allow lamp to cool 10 minutes before replacing Lamp Specifications Lamp socket / base: G22 Part# UHI-S150DW/A/UVP UHI-S150DM/A/UVP CDM150/T6/830...
  • Page 11 Maximum ambient temperature (t Keep objects at least 2” (50mm) from sides of the fixture. Keep objects at least 6” from the top of the fixture. Cabinet or Closet Mounting The Transition may be mounted in a closet or cabinet on a hard surface such as wood, laminate, or metal.
  • Page 12: Dmx / Rdm Setup And Operation

    DMX / RDM Setup and Operation Controls and Indicators Transition controls and indicators as follows: o A three character seven-segment display o 4 push buttons: Menu, (+), (-), and Enter o Power (red) and signal (green) indicator LED’s The seven-segment display shows the address number (1-508) and the Demo mode (OFF, d1, d2).
  • Page 13: Display Messages

    Display Messages Normal Messages Displayed for 1 second after power is applied. This is the RDM manufacturer device identification number Indicates that the unit is initializing the diachronic filters 001 – 508 The first DMX address Transition will respond to. Top menu item.
  • Page 14 RDM Functionality Transition is compliant with the RDM v1.0 standard and can be used with the Wybron Info-Trace system or other RDM systems. By definition, all required RDM parameters are supported including, discovery, device info, DMX start address, identify device, etc.
  • Page 15: Service

    Lamp Replacement DANGER: Disconnect fixture from line voltage before replacing lamp. WARNING: Lamp and lamp mounting surfaces are hot! Allow lamp to cool before replacing.  Disconnect fixture from AC power.  Remove lamp plate by removing mounting screws as shown in figure 1.1 and pull lamp assembly straight back from reflector.
  • Page 16 Cleaning the Color Filters It is recommended that the color filters be only cleaned with low-pressure air without disassembling the color filters from the motor shafts. If the color module must be disassembled to clean the dichroic filters take careful note of the location and offset height of the individual color flags. Color filters must be reassembled in exactly the same orientation and correct heights to ensure proper operation! CAUTION:...
  • Page 17: Flash Reprogramming

    DMX/RDM port using an Infogate gateway and the Infogate application. Transition firmware updates can be found at www.wybron.com. Specific instructions for upgrading firmware in Transition and other Wybron equipment can be found in the Infogate User Manual, Firmware Upgrades section.
  • Page 18: Warranty Information

    Warranty Information WYBRON, INC. warrants to the original owner or retail customer that for a period of one year from date of delivery of a portable system or energization of a permanently installed system (up to a maximum of 18 months from delivery) its products will be free from defects in materials and workmanship under normal use and service.
  • Page 19 Figure 2.1 Figure .2...