Wybron InfoTrace DPS850 User Manual

Wybron dimmer / power supply user manual

Advertisement

Quick Links

DPS850
User Manual
Dimmer / Power Supply
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the InfoTrace DPS850 and is the answer not in the manual?

Questions and answers

Summary of Contents for Wybron InfoTrace DPS850

  • Page 1 DPS850 User Manual Dimmer / Power Supply...
  • Page 2: Table Of Contents

    CONTENTS Declaration of Conformity ……….……………………….3 Safety Information………………….………………………4 Introduction…………………………………………………5 Installation…………………………………………………..6 Setup and Configuration…………………………………..7 Menu tree……………………………………………………8 InfoTrace……………………………………………….……9 InfoTrace System Connection Diagram…………………11 RDM functionality………………………………………….12 Maintenance……………………………………………….13 Specifications…..………….………………………………14 Warranty Information………..………………………….…15...
  • Page 3: Declaration Of Conformity

    Declaration of Conformity Page...
  • Page 4: Safety Information

    For questions, contact Wybron at 1-800-624-0146 or visit www.wybron.com. Product Modification Warning Wybron, Inc. products are designed and manufactured to meet the requirements of United States and International safety standards. Modifications to the products could affect safety and render the product non-compliant to relevant safety standards.
  • Page 5: Introduction

    Introduction The DPS850 is a combination dimmer / power supply allowing the user to create a stand alone fixture from a conventional lighting fixture and theatrical accessory. The DPS850 accepts 115 – 240VAC 50/60Hz input power and DMX and provides up to 800 watts of dimming for the fixture, as well as DC power and control signal for theatrical accessories including scrollers, gobo rotators, and dichroic color mixers.
  • Page 6: Installation

    NEXERA The DPS850 can be configured as an integral part of the Nexera fixture. In this configuration the DPS850 dimmed output is hard wired to the Nexera lamp assembly eliminating the lamp connection as a potential point of failure. The DPS850 can either be hung from pipe near the Nexera fixture or bolted to the Nexera yoke.
  • Page 7: Setup And Configuration

    Setup and Configuration The DPS850 can be set up and configured locally using the four button user interface or remotely with the InfoGate system. USER INTERFACE Indicator LED’s Three LED indicators are located to the left of the accessory output XLR connector to provide instant information as to the state of the DPS850.
  • Page 8: Menu Tree

    __001 Current DMX address _ Adr_ 001-512 _ Foc_ _ Loc_ 0-100 __LOS_ dLy, OFF, ON Adr (Address) Use this menu item to modify the DMX address the DPS850 is set to respond to. Press the Enter button to choose this menu item then use the + and – buttons to modify the dimmer’s DMX address.
  • Page 9: Infotrace

    (RDM), to facilitate remote addressing and diagnostics for potentially every piece of equipment mounted on a rig. InfoGate works with all Wybron manufactured IT products and all RDM-compatible equipment from any other manufacturer. In addition, any non-RDM equipment can be upgraded with the installation of an...
  • Page 10 Wybron's IT equipment (Coloram IT, CXI IT, Eclipse IT, and Eclipse II IT) is equipped with a series of sensors that can relay a wealth of information to InfoGate.
  • Page 11: Infotrace System Connection Diagram

    . InfoTrace System Connection Diagram 5 pin cable 5 pin cable 4 pin cable Lighting console Ethernet cable Router Infogate DPS850 InfoGate...
  • Page 12: Rdm Functionality

    RDM FUNCTIONALITY The DPS850 is an ANSI E1.20 – 2006 RDM compliant device. When used with the InfoGate gateway and software it can be configured and monitored remotely. Besides the baseline RDM functionality such as discoverability, identify, and DMX start address, the DPS850 provides additional RDM functions. Personality The manner in which the DPS850 responds to a loss of DMX can be configured through an RDM system.
  • Page 13: Maintenance

    The DPS850 can operate with any incandescent lamp rated 100 – 240VAC, 800W or lower. ACCESSORY OUTPUT The DPS850 is compatible with Forerunner, Nexera LX, and Wybron IT equipment. DO NOT USE COLORAM II EQUIPMENT WITH THE DPS850 Pinout of the accessory output is as follows:...
  • Page 14: Specifications

    PHYSICAL Length: Width: Height: Weight: Input cord length: Output cord length: ELECTRICAL (Dimmer) Number of dimmers: Input voltage: Minimum dimmer load: Maximum dimmer load: Rise time: Circuit protection: ELECTRICAL (Power supply) Maximum load: Circuit protection: ENVIRONMENTAL Ambient temperature: Relative humidity: Cooling: Specifications 7.750”...
  • Page 15: Warranty Information

    Warranty Information WYBRON, INC. warrants to the original owner or retail customer that for a period of one year from date of delivery of a portable system or energization of a permanently installed system (up to a maximum of 18 months from delivery) its products will be free from defects in materials and workmanship under normal use and service.

This manual is also suitable for:

Infotrace it dps850

Table of Contents