Connecting devices (binding)

Binding room setpoint generators/sensors with the evohome controller

T87 RF
DTS92A(E)
Option
evohome controller
If you do not follow the
GUIDED CONFIGURATION, observe the
steps on your evohome controller:
1. Press "SET"
on the evohome controller
and keep it pressed for 3 seconds.
2. Press the green check mark
3. Press ADD ROOM.
4. Select the room that you want to add and
then select UNDERFLOOR HEATING.
5. A room setpoint generator/sensor
HCW82/HCF82/DTS92/T87RF has to be
connected with the evohome controller
for each room that is controlled with the
underfloor heating controller.
Repeat this procedure for each room (zone)
with an underfloor heating.
Connecting devices (binding)
HCW82
HCF82
evotouch
.
With the evohome controller each
zone can be controlled separately
with an individual time program.
For information on installing the device please
read the evohome installation instructions.
!
Ensure that the room that you add to
the evohome controller corresponds to
the correct underfloor heating room.