Download Print this page
Dormakaba TS 97 FL XEA Mounting Instructions

Dormakaba TS 97 FL XEA Mounting Instructions

Advertisement

Quick Links

dormakaba Deutschland GmbH
Postfach 4009
58256 Ennepetal
EN 1154:1996/A1:2002/AC:2006
0432-CPR-00026-58
EN 1155: 1997/A1: 2002/AC:2006
DOP_0172
Contents
1
About this document
1.1
Contents and purpose
1.2
Target group
1.3
Other applicable documents
1.4
Documents storage
1.5
Safety instructions
1.6
Symbols used
1.6.1
Tool icons
2
Safety
2.1
Intended use
2.2 Prerequisites for the operation of hold-open
systems
2.3 Requirements for the electrical installation by the
customer
3
Product description
3.1
Technical data
3.2 Optional components
4
Mounting
4.1
Mounting variants
4.2 Mounting the door closer and slide rail
4.3 Mount lever arm
4.4 Adjust door closer
4.5 Mount the cladding
4.6 Set the doorstop
4.7 Function test
4.7.1
Freewheel function
4.7.2
Close door
5
Disassembly, recycling and disposal
TS 97 FL XEA
Mounting instructions
19
3 8 3-6 1 1 4
1
About this document
1.1
Contents and purpose
1
1
This manual describes the installation, startup,
1
maintenance and disassembly of the TS 97 FL XEA
1
door closer. The manual's picture section is partly
1
supported by text in this section of the manual.
1
1.2
Target group
1
1
The hold-open system's mounting, commissioning,
1
maintenance and disassembly must only be carried
1
out by qualified personnel that have been authorized
by dormakaba. The acceptance inspection must only
2
be carried out by qualified personnel certified for this
by dormakaba.
2
1.3
Other applicable documents
2
2
The following documents belong to the unit's
3
complete documentation and must be observed:
3
• Drilling template
3
• Picture section for mounting instructions
3
• General design approval
3
• Information sheet about the use of hold-open
3
systems
3
1.4
Documents storage
3
3
This manual must be kept during the service life of the
3
product and must be passed on with the product.
3
1.5
Safety instructions
3
CAUTION
This signal word indicates a situation of
potential risk, which could lead to minor or
slight injury if not averted.
1.6
Symbols used
1.
2.
Step-by-step graphics
WN 059870 45532/13715
2019-08
EN

Advertisement

loading
Need help?

Need help?

Do you have a question about the TS 97 FL XEA and is the answer not in the manual?

Questions and answers

Summary of Contents for Dormakaba TS 97 FL XEA

  • Page 1 Intended use out by qualified personnel that have been authorized 2.2 Prerequisites for the operation of hold-open by dormakaba. The acceptance inspection must only systems be carried out by qualified personnel certified for this 2.3 Requirements for the electrical installation by the by dormakaba.
  • Page 2 Additional requirements apply for use as fire/smoke protection closure in conjunction with external RMZ and RM. A separate verification of suitability is required for the respective fire/smoke protection door. TS 97 FL XEA WN 059870 45532 2019-08...
  • Page 3 Optional components Mount the cladding • Concealed cable loop for the door closer’s power 11 - 13 supply via the door leaf, e.g. dormakaba KÜ 480 and Carry out the mounting according to the enclosed LK12 illustrated instructions. • 24 V DC power supply and smoke detector panel, e.g.
  • Page 4 Deutschland GmbH DORMA Platz 1 58256 Ennepetal Germany T: +49 2333 793-0 F: +49 2333 793-4950 www.dormakaba.com...