Curtis C1000AP Service Manual

Dual airpot brewers

Advertisement

SERVICE MANUAL
C1000AP & C1000APT
DUAL AIRPOT BREWERS
Wilbur Curtis Co., Inc.
Montebello, California 90640  Telephone 323/837-2300  Fax 323/837-2406

Advertisement

Table of Contents
loading

Summary of Contents for Curtis C1000AP

  • Page 1 SERVICE MANUAL C1000AP & C1000APT DUAL AIRPOT BREWERS Wilbur Curtis Co., Inc. Montebello, California 90640  Telephone 323/837-2300  Fax 323/837-2406...
  • Page 2: Table Of Contents

    Warranty ......... . CARTON CONTENTS ITEM C1000 AP or APT COFFEE BREWER BREW CONE, UNIVERSAL SERVICE MANUAL FILTER PAPER FITTING, 1/4 x 3/8 FLARE ELBOW C1000AP & APT ROUGH-IN DRAWING C1000AP C1000APT C1000AP C1000APT Inside Front Cover Inside Front Cover C1000AP...
  • Page 3: Introduction

    This manual applies to Curtis Dual Station Airpot Brewer models C1000AP and C1000APT. Model C1000AP is designed for use with Curtis Airpots CAP-1 thru CAP-5, and other insulated dispensers up to 13¾" tall when opened for filling (see illustration, Step 3 in Coffee Brewing). Starting early in 1994, this brewer was increased in height to accommodate the larger "Deluxe"...
  • Page 4: Coffee Brewing

    C1000AP & C1000APT Airpot Brewer COFFEE BREWING With a clean filter in place, pour ground coffee into the brew cone. You may need to experiment to determine the cor- rect quantity of ground coffee for your tastes, but a consistent measure of ground coffee is necessary for controlling the quality of flavor in your brewed...
  • Page 5: Care & Maintenance

    PRODUCTS WILL VOID YOUR WARRANTY. TROUBLESHOOTING These procedures apply specifically to model C1000AP-10 and C1000APT-10. They also apply to airpot brewers with other dash numbers which are based on the -10 schematic, primary units rated 220 volts, 5100 watts, three wire plus ground. If the serial nameplate electrical rating differs, some measured volt- ages, currents, and resistances will be different than shown on the standard -10 schematic.
  • Page 6 C1000AP & C1000APT Airpot Brewer TROUBLE SHOOTING CONTINUED: PROBLEM: WATER DOES NOT FLOW INTO HEATING TANK. POSSIBLE CAUSE 3. Grounded probe 4. Defective water level control board PROBLEM: WATER HEATING TANK OVERFLOWING. POSSIBLE CAUSE 1. Defective water inlet valve 2. Probe limed-up 3.
  • Page 7 C1000AP & C1000APT Airpot Brewer TROUBLE SHOOTING CONTINUED: PROBLEM: WATER IN TANK DOES NOT REACH PROPER TEMPERATURE POSSIBLE CAUSE 4. Burned out heating element PROBLEM: WATER BOILING, HEATING ELEMENTS DO NOT SHUT OFF. POSSIBLE CAUSE 1. Defective thermostat 2. Defective contactor PROBLEM: WATER NOT FLOWING FROM SPRAYHEAD.
  • Page 8: Parts Breakdown

    C1000AP & C1000APT Airpot Brewer ILLUSTRATED PARTS BREAKDOWN [ 6 ]...
  • Page 9 C1000AP & C1000APT Airpot Brewer ILLUSTRATED PARTS BREAKDOWN [ 7 ]...
  • Page 10: Parts List

    C1000AP & C1000APT Airpot Brewer PARTS LIST INDEX PART DESCRIPTION Nº Nº WC-5421 COVER, TOP SS WC-1809 FAUCET, PS/HPS SERIES HOT WTR WC-1806 SEAT CUP, SILICONE F0R WC-1809 WC-3621 BREW CONE, UNIVERSAL 7.1" DIA. WC- 114R SWITCH, ROCKER 120V SPST 15A...
  • Page 11: Wiring Diagram

    C1000AP & C1000APT Airpot Brewer [ 9 ]...
  • Page 12: Warranty

    Product Warranty Information The Wilbur Curtis Company certifies that its products are free from defects in material and workmanship under normal use. The fol- lowing limited warranties and conditions apply: 3 Years, Parts and Labor, from Original Date of Purchase on digital control boards. 2 Years, Parts, from Original Date of Purchase on all other electrical components, fittings and tubing.

This manual is also suitable for:

C1000apt

Table of Contents