White Rodgers 755-50 Installation Instructions Manual
White Rodgers 755-50 Installation Instructions Manual

White Rodgers 755-50 Installation Instructions Manual

Electric water heater control

Advertisement

Available languages

Available languages

WHITE-RODGERS
Operator: Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
This control is a dual-function control having a tempera-
ture control in series with a high-limit control.
The temperature control is a normally closed SPST switch
which opens on a rise in temperature and will control one
heating element.
THIS CONTROL MUST BE INSTALLED BY A QUALI-
FIED INSTALLER.
All wiring must conform to local and national electrical
codes and ordinances.
This control is a precision instrument, and should be
handled carefully. Rough handling or distorting compo-
nents could cause the control to malfunction.
This control has been accurately calibrated at the factory.
Any attempt to re-calibrate this control will void the White-
Rodgers warranty.
WARNING
!
Do not use on circuits exceeding specified volt-
ages. Higher voltages will damage control and
could cause shock or fire hazard.
If in doubt about whether your wiring is millivolt,
low or line voltage, have it inspected by a quali-
fied heating and air conditioning contractor or a
licensed electrician.
AC ELECTRICAL RATINGS
UL and CSA recognized for resistive loads.
Temp Control
Voltage
30 Amps
120-250 VAC
25 Amps
277 VAC
12.5 Amps
480 VAC
WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
The limit control is a normally closed DPST switch which
opens on a rise in temperature to limit the maximum
allowable temperature. It has manual reset.
Both switches are calibrated to meet the requirements for
typical residential type storage tank water heaters.
Temperature Ratings:
Limit Control
40 Amps
40 Amps
25 Amps
Printed in U.S.A.
755-50
Electric Water Heater Control

INSTALLATION INSTRUCTIONS

CAUTION
!
To prevent electrical shock and/or equipment
damage, disconnect electric power to system at
main fuse or circuit breaker box until installation
is complete.
Label all wires prior to disconnection when ser-
vicing controls. Wiring errors can cause improper
and dangerous operation.
Following installation or replacement, follow
appliance manufacturers' recommended instal-
lation/service instructions to insure proper op-
eration.
Temperature control - Variable 90 to 150 F (32 to
Limit control - Fixed 170 F (77 C) with manual reset
DESCRIPTION
PRECAUTIONS

SPECIFICATIONS

66 C)
PART NO. 37-5784A
9715

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 755-50 and is the answer not in the manual?

Questions and answers

Summary of Contents for White Rodgers 755-50

  • Page 1: Installation Instructions

    Temperature control - Variable 90 to 150 F (32 to Limit control - Fixed 170 F (77 C) with manual reset Limit Control 40 Amps 40 Amps 25 Amps Printed in U.S.A. 755-50 DESCRIPTION PRECAUTIONS CAUTION SPECIFICATIONS 66 C) PART NO. 37-5784A...
  • Page 2: Installation

    INSTALLATION All wiring must conform to local and national electrical codes and ordinances. Connect in accordance with wiring diagrams provided by the equipment manufacturer. If none are provided, the following represents a typical installation. SIngle Element Circuit for Full Power Disconnect Through Both Power Conductors SETTING THE DIAL Adjust temperature setting by inserting a screwdriver into...
  • Page 3: Instructions D'installation

    66 C (90 à 150 F) Commande de limite - Fixe à 77 C (170 F) avec réarmement manuel Commande de limite 40 A 40 A 25 A Imprimé aux États-Unis 755-50 DESCRIPTION PRÉCAUTIONS ATTENTION SPÉCIFICATIONS No. DE PIÉCE 37-5784A 9715...
  • Page 4 INSTALLATION Tous les branchements doivent être conformes aux codes et règlements Brancher selon les schémas fournis par le fabricant de l’équipement. Si aucun n’est fourni, le schéma suivant représente une installation typique. Circuit à un seul élément avec débranchement complet des deux fils d’alimentation RÉGLAGE DU CADRAN Pour régler la température, insérer un tournevis dans la...
  • Page 5: Instrucciones De Instalacion

    Control de temperatura - Variable 32 a 66 C (90 a 150 F) Control Control de límite - Fijo 77 C (170 F) con reajuste de Límite manual 40Amp 40Amp 25Amp Impreso en EE.UU 755-50 de Agua Eléctrico DESCRIPCION PRECAUCIONES PRECAUCION ESPECIFICACIONES No. DE PARTE 37-5784A 9715...
  • Page 6 INSTALACION Todo el cableado tiene que cumplir con las regulaciones y los Conéctelo según los diagramas de cableado ofrecidos por el fabricante del equipo. Si no viene ninguno incluido, a continuación se presenta una instalación típica. Circuito del elemento único para energía completa desconéctelo a través de ambos conductores de energía...

Table of Contents