Integral Heat Meter Display (If Fitted) - Bosch WORCESTER Greenstar HIU User Instructions

Heat interface unit for connection to a district heating system supplying heating and domestic hot water
Hide thumbs Also See for WORCESTER Greenstar HIU:
Table of Contents

Advertisement

3

Integral heat meter display (if fitted)

1
2
Fig. 2
Integral heat meter display
Item Description
1
Optical sensor
Not used
2
Monthly value index
When displayed, shows the month that the values on
the display are recorded for.
– Displays previous 1 - 18 months
3
Flow temperature
Displays when showing flow temperature in service
level menu
4
Return temperature
Displays when showing return temperature in
service level menu
5
Communication
Not used
6
Service level
Displays when in service level menu
Table 3
Greenstar HIU – 6 720 810 422 (2015/05)
3
4
5
6
7
8
Item Description
7
Cooling use
Not used
8
Additional pulse input 1 & 2
Not used
9
Impellor wheel in operation
Displays when a demand is active
10 Units
Displays units of measure
11 Navigation button
Cycles through menu structure