White Rodgers 1F80ST-0471 Installation And Operating Instructions Manual

White Rodgers 1F80ST-0471 Installation And Operating Instructions Manual

80 series thermostat with automatic heat/cool changeover option

Advertisement

Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
APPLICATIONS
THERMOSTAT APPLICATION GUIDE
Description
Gas or Oil Heat
Electric Furnace
Heat Pump (No Aux. or Emergency Heat)
Heat Pump (with Aux. or Emergency Heat)
Systems with up to 3 Stages Heat, 2 Stages Cool
Heat Only Systems
Millivolt Heat Only Systems - Floor or Wall Furnaces
Cool Only Systems
Hydronic (Hot Water) Zone Heat - 2 Wires
Hydronic (Hot Water) Zone Heat - 3 Wires

SPECIFICATIONS

Electrical Rating:
Battery Power . . . . . . . . . . . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire . . . . . . . . . . . . . . . . . . . . . . . . . 20 to 30 VAC
Terminal Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45° to 90°F (7° to 32°C)
Differential (Single Stage) . . . . . . . . . . . . . . . . . . . . Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) . . . . . . . . . . . . . . . . . . . . . Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient. . . . . . . . . . . . . . . . . . . . . . . . . . 32° to +105°F (0° to +41°C)
Operating Humidity . . . . . . . . . . . . . . . . . . . . . . . . . 90% non-condensing max.
Shipping Temperature Range . . . . . . . . . . . . . . . . . -40° to +150°F (-40° to +65°C)
Dimensions Thermostat. . . . . . . . . . . . . . . . . . . . . . 3.4"H x 4.4"W x 1.3"D
CAUTION
!
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or circuit
breaker box until installation is complete.
Index
80 Series Thermostat with
Automatic Heat/Cool Changeover Option
Single Stage or Heat Pump
Installation and Operating Instructions for Model:
Model
1F80ST-0471
1F86ST-0471
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
Yes
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this
product may replace a product that contains mercury.
Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
Page
spilled mercury and place in a sealed container. For proper
2
disposal of a product containing mercury or a sealed
3
container of spilled mercury, place it in a suitable shipping
3
container. Refer to www.white-rodgers.com for location to
4
send product containing mercury.
6
6
8
www.white-rodgers.com
Programming Choices
5/2 Day
5/1/1 Day
Non-Programmable
Non-Programmable
1F80ST-0471 Thermostat
with Spanish Display
PART NO. 37-6952A
0827

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 1F80ST-0471 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for White Rodgers 1F80ST-0471

  • Page 1: Specifications

    Installation and Operating Instructions for Model: Model 1F80ST-0471 5/2 Day 1F86ST-0471 1F80ST-0471 Thermostat with Spanish Display ATTENTION: MERCURY NOTICE This product does not contain mercury. However, this product may replace a product that contains mercury. Mercury and products containing mercury must not be discarded in household trash.
  • Page 2: Remove Old Thermostat

    INSTALLATION WARNING Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code. Remove Old Thermostat A standard heat/cool thermostat consists of three basic parts: 1. The cover, which may be either a snap-on or hinge type. 2.
  • Page 3: Wiring Connections

    WIRING CONNECTIONS Refer to equipment manufacturers' instructions for specifi c system wiring information. After wiring, see CONFIGURATION section for proper thermostat confi guration. Refer to 37-6754 for 1F80-0471/1F86-0471 wiring diagram specifi cations. Terminal Designation Description O/B... (SS) Power closed for 3 wire zone (HP) Changeover valve for heat pump Compressor Relay Y...
  • Page 4: Installer/Configuration Menu

    INSTALLER/CONFIGURATION MENU Press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to advance to the next menu item. Press to change a menu item. Shaded items are not available on 1F86. MENU PRESS DISPLAYED...
  • Page 5 INSTALLER/CONFIGURATION MENU 4. Energy Management Recovery: (this step is skipped if confi gured to be non-programmable). Energy Management Recovery (E) On enables the thermostat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify.
  • Page 6: Operating Your Thermostat

    OPERATING YOUR THERMOSTAT Choose the Vent Setting (Auto or On) Set the VENT Switch to Auto or On. Vent Auto is the most commonly selected setting and runs the fan only when the heating or cooling system is on. Vent On runs the fan continuously for increased air circulation or to allow additional air cleaning.
  • Page 7 Energy Saving Factory Pre-Program The 1F80ST-0471 thermostats are programmed with the energy saving settings shown in the table below for all days of the week. If this program suits your needs, simply set the thermostat clock and press the Arrancar button.
  • Page 8: Troubleshooting

    TROUBLESHOOTING Reset Operation Note: When thermostat is reset, installer confi guration menu settings and programming will reset to factory settings. If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, you can reset the thermo- stat by removing the wires from terminals R and C (do not short them together) and removing batteries for 2 minutes.