Gas pressure regulator with hon 630 pilot
Hide thumbs Also See for HON 5020:
Table of Contents

Advertisement

Pilot connection lines
Pilot pressure
sections
How the pilot works
HON 5020 gas pressure regulator with HON 630 pilot
The pilot features the following fittings:
Figure
Figure
 The inlet pressure is conveyed into the load limiting stage via the fine mesh filter.
 The outlet pressure is conveyed into the control stage and produces a force component
that acts on the double diaphragm system from above.
 The pilot's set screw is used to tighten the pilot spring, producing a force component
that acts on the control stage's double diaphragm system from below.
 The force components being exerted on the double diaphragm system are used by the
system in order to compare the setpoint and the process value. Depending on the out-
let pressure and on the set setpoint, a small/large gap relative to the load limiting stage
will be cleared. This, in turn, will result in an accordingly low/high loading pressure be-
ing passed on to the load limiting stage.
 Inside the load limiting stage, the double diaphragm system (much like the control
stage) performs a setpoint/process value comparison between the loading pressure
acting from above and the outlet pressure acting from below.
No.
Description
1
Port for inlet pressure line
Ø10, M 14 x 1.5
2
Inlet pressure gauge fitting
3
Loading pressure gauge fitting
4
Port for outlet pressure sensing line
Ø12, M 14 x 1.5
 Optionally with pressure gauge for
outlet pressure and protection against
overpressure
5
Port for outlet pressure process line
6
Vent line connection
Ø12, M 14 x 1.5 (ambient pressure com-
pensation)
7
Inlet pressure fitting
Color
Description
Meaning
Inlet pressure
Loading
pressure
Motorization
pressure
Outlet pres-
sure
Atmospheric
pressure