The data plate gives the product identification and
technical data; listed below is the meaning of the vari-
ous information given on it.
F.Mod ..................... factory description of product
Comm. Model......... commercial description
PNC........................
production number code
Ser. Nr. ..................
serial number
AC 230V 1N .......... power supply voltage
50 Hz...................... power supply frequency
Max 2.85 kW .......... max. power input
Nominal 2.85 kW.... power input as per factory settings
2014 ....................... year of construction
CE .......................... CE marking
IPX4 ....................... protection rating
Electrolux Professional S.p.A. - Viale Treviso, 15 -33170
Pordenone (Italy) ..... Manufacturer
The data plate is located on the right side panel of the
equipment.

Figure 2 Position of marking

ATTENTION!
Do not remove, tamper with or make the
machine marking illegible.
ATTENTION!
Refer to the data given on the machine
marking for relations with the Manufac-
turer (e.g. when ordering spare parts,
etc.).
ATTENTION!
When scrapping the machine, the mark-
ing must be destroyed.
B5
Equipment identification
B5.1
How to identify the technical data
To identify the technical data (Figure 3), read the fac-
tory description of the product (F. Mod.) on the data
plate, identify the main machine data and consult
Table 1 "Main technical characteristics, performance
and consumption".
2014
F.Mod.
NUC1DDRUKP
Comm. Model
NUC1DDRUKP
PNC
9CGX 400130 00
Ser.Nr. 40116001
EL
AC 230V 1N
50 Hz
Max
2.85 kW
Nominal
2.85 kW
Min
IPX4
Electrolux Professional spa - Viale Treviso, 15 - 33170 Pordenone (Italy)
F.Mod. NUC1DDRUKP
Electrolux Professional spa - Viale Treviso, 15
D1 "Main technical characteristics"
MODEL
Supply
Power supply voltage
Frequency

Figure 3 Technical data identification

B5.2
How to interpret the factory description
The factory description on the data plate has the fol-
lowing meaning (some examples are given below):
Single skin version
(1)
(2)
(3)
(4)
N
UC
1
D
Description of variables
(1) Brand
N = To brand.
(2) Machine type
UC = Under Counter
(3).. (8)
1 = Single phase, DD = Detergent pump + drain
pump, R = Additional basket included, UK = United
Kingdom, P = with plug provided
B6
Copyright
This manual is intended for consultation exclusively by
the operator and can be given to third parties only with
the written permission of Electrolux Professional S.p.A.
B7
Liability
The instructions are updated to the month and year
shown in the box located at the bottom right of the
cover. The edition corresponds to the revision number
of the manual. Every new edition replaces and cancels
the previous ones.
DOC. NO.
EDITION: 1
Document
Number
Edition

Figure 4 Example of document identification data

The Manufacturer declines any liability for damage and
malfunctioning caused by:
non-compliance with the"Definitions" instructions
contained in this manual;
repairs not carried out in a workmanlike fashion, and
replacements using spare parts different from those
specified in the spare parts catalogue (the fitting and
use of non-original spare parts and accessories can
negatively affect machine operation);
NUC1DDRUKP
Electric
V
400 3N
Hz
50
(5)
(6)
(7)
D
R
UK
5956.6H4.00
05.2014
Month
Year
(8)
P
7