This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the
indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water
leaving the system, as specified in ANSI/NSF 42/53.
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirements
Chlorine Taste/Odor
50%
*
Particulate Class II
85%
Contaminant
NSF Reduction
Reduction
Requirements
Lead: @ pH 6.5
0.01mg/L
Lead: @ pH 8.5
0.01mg/L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.005 mg/L
p-dichlorobenzene
0.075 mg/L
Toxaphene
0.003 mg/L
Carbofuran
0.04 mg/L
Substance Reduction
NSF Reduction
Aesthetic Effects
Requirement
Chlorine Taste/Odor
50%
*
Particulate Class II
85%
Contaminant
NSF Reduction
Reduction
Requirement
Lead: @ pH 6.5
0.01mg/L
Lead: @ pH 8.5
0.01mg/L
Mercury: @ pH 6.5
0.002 mg/L
Mercury: @ pH 8.5
0.002 mg/L
Benzene
0.005 mg/L
p-dichlorobenzene
0.075 mg/L
Toxaphene
0.003 mg/L
Carbofuran
0.04 mg/L
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-NL240V: Change cartridge at least every 6 months.
Use replacement cartridge NL240V, part #4396509. 2005
suggested retail price of $35.99 U.S.A./$59.95 Canada. Prices
are subject to change without notice.
Model WF-L400V: The filter monitor system measures the
amount of water that passes through the filter and alerts you to
replace the filter. When 90% of the filter's rated life is used, the
filter indicator light changes from green to yellow. When 100% of
the filter's rated life is used, the filter indicator light changes from
yellow to red, and it is recommended that you replace the filter.
Use replacement cartridge L400V, part #4396509. 2005
suggested retail price of $35.99 U.S.A./$59.95 Canada. Prices are
subject to change without notice.
The product is for cold water use only.
*
Class II particle size: >1 to <5
**
Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
***
® NSF is a registered trademark of NSF International.
Base Grille Water Filtration System
Tested and certified by NSF International against ANSI/NSF Standard 42
for the reduction of Chlorine Taste and Odor, Particulate Class II*; and
against ANSI/NSF Standard 53 for the reduction of Lead, Mercury,
Benzene, Toxaphene, p-dichlorobenzene, and Carbofuran.
Model WF-NL240V/NL240V Capacity 240 Gallons (908 Liters)
Average
Influent Challenge
Influent
Concentration
1.94 mg/L
2.0 mg/L ± 10%
833,333/mL
At least 10,000
particles/ml
Average
Influent Challenge
Influent
Concentration
0.15 mg/L***
0.15 mg/L ± 10%
0.148 mg/L***
0.15 mg/L ± 10%
0.006 mg/L
0.006 mg/L ± 10%
0.0061 mg/L
0.006 mg/L ± 10%
0.014 mg/L
0.015 ± 10%
0.235 mg/L
0.225 ± 10%
0.014 mg/L
0.015 ± 10%
0.077 mg/L
0.080 ± 10%
Model WF-L400V/L400V Capacity 400 Gallons (1514 Liters)
Average
Influent Challenge
Influent
Concentration
1.94 mg/L
2.0 mg/L ± 10%
833,333/mL
At least 10,000
particles/ml
Average
Influent Challenge
Influent
Concentration
0.15 mg/L***
0.15 mg/L ± 10%
0.148 mg/L***
0.15 mg/L ± 10%
0.0061 mg/L
0.006 mg/L ± 10%
0.0061 mg/L
0.006 mg/L ± 10%
0.014 mg/L
0.015 ± 10%
0.235 mg/L
0.225 ± 10%
0.014 mg/L
0.015 ± 10%
0.077 mg/L
0.080 ± 10%
Maximum
Average
Effluent
Effluent
0.05 mg/L
0.05 mg/L
100,000/mL**
40,667/mL
Maximum
Average
Effluent
Effluent
0.001 mg/L
0.001 mg/L
0.003 mg/L
0.001 mg/L
0.0002 mg/L
0.0002 mg/L
0.0009 mg/L
0.00052 mg/L
0.0005 mg/L
0.0005 mg/L
0.0019 mg/L
0.0009 mg/L
0.0012 mg/L
0.001 mg/L
0.031 mg/L
0.0064 mg/L
Maximum
Average
Effluent
Effluent
0.05 mg/L
0.05 mg/L
100,000/mL**
40,667/mL
Maximum
Average
Effluent
Effluent
0.001 mg/L
0.001 mg/L
0.003 mg/L
0.0014 mg/L
0.0002 mg/L
0.0002 mg/L
0.0009 mg/L
0.00052 mg/L
0.0005 mg/L
0.0005 mg/L
0.0019 mg/L
0.0009 mg/L
0.0012 mg/L
0.001 mg/L
0.031 mg/L
0.0064 mg/L
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the
system.
Refer to the front cover or "Assistance or Service" section for the
Manufacturer's name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply
Water Pressure
Water Temperature
Service Flow Rate
Minimum %
Average %
Reduction
Reduction
97.4%
97.4%
88.0%
95.1%
Minimum %
Average %
Reduction
Reduction
99.3%
99.3%
97.9%
99.0%
96.60%
96.6%
85.2%
91.8%
96.06%
96.06%
99.1%
99.6%
92.7%
92.6%
61.03%
91.94%
Minimum %
Average %
Reduction
Reduction
97.4%
97.4%
88.0%
95.1%
Minimum %
Average %
Reduction
Reduction
99.3%
99.3%
97.9%
99.3%
96.60%
96.6%
85.2%
91.8%
96.06%
96.06%
99.1%
99.6%
92.7%
92.6%
61.03%
91.94%
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8°C)
0.5 gpm (1.9 L/min.) @ 60 psi.
13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents