DIAGNOSTICS & TROUBLESHOOTING
Troubleshooting (cont.)
VOLTAGE TEST POINTS - MINOTAUR CONTROL BOARD
FROM
COLOR
P1-1
BK
PI
P1-4
RD
P2-1
YL/RD
P2
P2-5
WH/RD
P2-6
TN
P3-1
WH/TN
P3-3
V
P3
P3-5
GY
P3-6
BU
P3-8
BU/YL
P4-1
OR/BK
P4
P4-3
TN/BK
P5-1
BU
P5
P5-3
TN/RD
P7
P7-1
WH
P8-1
YL
P8-3
YL/RD
P8
P8-6
P8 6
BK/WH
BK/WH
P8-7
WH
J1
J1-4
OR/BK
J2
J1-2
TN/BK
J2
J2-1
WH
4CKT PIN3
WH
4CKT PIN1
RD
3CKT PIN1
BU
* Voltage varies with Thermistor resistance (5 VDC Output with Thermistor unplugged)
5-10
n
vOLTAgE TEsT POINT chART
TO
COLOR
P1-2
WH
120VAC INPUT- CONSTANT WHEN PLUGGED IN
P1-2
WH
120VAC OUTPUT TO COMPRESSOR
P1-2
WH
120VAC INPUT- WATER FILTER SWITCH FEEDBACK
P1-2
WH
120VAC OUTPUT TO CONDENSER FAN
P1-2
WH
120VAC OUTPUT TO WATER VALVE
P1-1
BK
120VAC NEUTRAL FOR TRANSFORMER
P1-2
WH
120VAC OUTPUT TO HOT GAS VALVE
4CKT PIN2
RD/BK
12.8 VAC INPUT FROM TRANSFORMER
4CKT PIN2
RD/BK
12.8 VAC OUPUT TO RECIRCULATING PUMP
4CKT PIN2
RD/BK
12.8 VAC OUPUT TO DRAIN PUMP
P4-4
BK/WH
14 VDC OUTPUT TO USER INTERFACE
P4-4
BK/WH
COMMUNICATION
P5-2
BU
BIN Thermistor 1 to 4 VDC*
P5-4
TN/RD
EVAP Thermistor 1 to 4 VDC*
P7-2
WH
Unit Thermistor 1 to 4 VDC*
P8-2
GY
5VDC Reed Switch
P8-4
BR
5VDC INPUT Water Level Switch - When Water Present
P8 4
P8-4
BR
BR
14 VDC OUTPUT TO WATER LEVEL SENSOR
14 VDC OUTPUT TO WATER LEVEL SENSOR
P8-8
RD
14 VDC OUTPUT TO DIAMOND LED LIGHT
VOLTAGE TEST POINTS - DOTYK USER INTERFACE BOARD
J1-1
BK/WH
14 VDC INPUT TO UI
J1-1
BK/WH
COMMUNICATION
VOLTAGE TEST POINTS - DIAMOND LED
J2-2
RD
14 VDC TO DIAMOND LED LIGHT
VOLTAGE TEST POINTS - TRANSFORMERS
4CKT PIN4
BK
120 VAC INPUT TO TRANSFORMER
4CKT PIN2
RD
12.8 VAC OUTPUT FROM TRANSFORMER
3CKT PIN3
BU
9.4 VAC OUTPUT FROM TRANSFORMER
CONDITIONS