GAS PIPING, CONNECTIONS and Gas Regulator
Before connecting the gas supply, check the rating plate on the right side of the front cover to be sure that the heater is
rated for the same gas to which it will be connected.
In the United States: The installation must conform with local codes or, in the absence of local codes, the National Fuel
Gas Code ANSI Z223.1/NFPA 54.
In Canada: The Installation should conform with CGA B149 INSTALLATION CODES and /or local installation codes.
FOR NATURAL GAS
Maximum Capacity of pipe in Cubic Feet of Gas per Hour
for Gas Pressure of 0.5 Psig or less and a Pressure drop of
0.3 in Water Column.
(Based on a 0.60 Specific Gravity Gas) Btu numbers given
in thousands.
Nominal
Iron
Pipe
Internal
Size,
Diameter
inches inches
10
1/4
0.364
32
3/8
0.493
72
1/2
0.622
132
3/4
0.824
278
1
1.049
520
1 1/4
1.380
1050
1 1/2
1.610
1600
2
2.067
3050
2 1/2
2.469
4800
3
3.068
8500
4
4.026
17,500 12,000 9,700 8,300
FOR LP GAS
Maximum Capacity of Pipe in Thousands of
BTU per Hour of Undiluted Petroleum Gases
(at 11 inches Water Column Inlet Pressure)
(Based on a Pressure Drop of 0.5 Inch Water
Column).
Maximum Capacity of Semi-Rigid
Tubing in Thousands of BTU per Hour of
Undiluted Liquified Petroleum Gases (at 11
inches Water Column Inlet Pressure)
(Based on a Pressure Drop of 0.5 Inch Water
Column)
* Source National Fuel Gas Code NFPA 54, ANSI Z223.1 - No
Additional Allowance is necessary for an ordinary number of fittings
GAS LINE SIZING
Le ngth of Black Iron Pipe , Fe e t
20
30
40
50
22
18
15
14
49
40
34
30
92
73
63
56
190
152
130
115
350
285
245
215
730
590
500
440
1100
890
760
670
2100
1650 1450
1270 1150 1050
3300
2700 2300
2000 1850 1700 1600 1500 1400 1250
5900
4700 4100
3600 3250 3000 2800 2600 2500 2200
7,400 6,80 6,200 5,800 5,400 5,100 4,500
Nominal
Iron Pipe
Size,
Inches
Outside
Diameter,
Inch
Follow boxed numbers for piping just one Aquastar 125FX
(example: 3/4" B.I. Natural Gas pipe for 30 ft. will handle
152,000 btu's). For multiple appliances combine the total
btu input load and then refer to applicable chart below.
60
70
80
90
12
11
11
10
27
25
23
22
50
46
43
40
105
96
90
84
195
180
170
160
400
370
350
320
610
560
530
490
990
930
Black Iron Pipe
Length of Pipe, Feet
10
20
30
40
50
1/2
275 189 152
129 114 103
3/4
567 693 315
267 237 217 196 185 173
1
107 732 590
504 448 409 378 346 322
1 1/4
220 149 121
103 913 834 771 724 677
1 1/2
330 229 185
155 141 127 118 108 102
2
622 433 346
299 264 239 220 204 192 1811 1606 1496
Length of Tubing, Feet
10
20
30
40
3/8
39
26
21
19
1/2
92
62
50
41
5/8
199 131
107
90
3/4
329 216
181 145
7/8
501 346
277 233
100
125
150
175
9
8
8
7
21
18
17
15
38
34
31
28
79
72
64
59
150
130
120
110
305
275
250
225
460
410
380
350
870
780
710
650
1130 1050
2000 1850 1700
4,100 3,800 3500
60
70
80
90
100
125
96
89
83
78
162
146
307
275
630
567
976
866
Copper
50
60
70
80
90
100
_
_
_
_
_
37
35
31
29
27
79
72
67
62
59
131
121 112 104
95
198
187 164 155 146 138
200
6
14
26
55
100
210
320
610
980
150
69
63
132
252
511
787
_
26
55
90
9