Page 1
Distributor of Teledyne LeCroy: Excellent Integrated System Limited Datasheet of CP015-CF01 - HIGH SPEED CURRENT SHUNT CP015 Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com Excellent Integrated System Limited Excellent Integrated System Limited Stocking Distributor Stocking Distributor Click to view price, real time Inventory, Delivery & Lifecycle Information: Click to view price, real time Inventory, Delivery &...
Distributor of Teledyne LeCroy: Excellent Integrated System Limited Datasheet of CP015-CF01 - HIGH SPEED CURRENT SHUNT CP015 Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com Operator’s Manual AP015 Current Probe...
Page 3
Distributor of Teledyne LeCroy: Excellent Integrated System Limited Datasheet of CP015-CF01 - HIGH SPEED CURRENT SHUNT CP015 Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com...
Page 4
Distributor of Teledyne LeCroy: Excellent Integrated System Limited Datasheet of CP015-CF01 - HIGH SPEED CURRENT SHUNT CP015 Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com AP015 Current Probe Operator’s Manual October 2013...
Spare parts, replacement parts and repairs are warranted for 90 days. In exercising its warranty, Teledyne LeCroy, at its option, will either repair or replace any assembly returned within its warranty period to the Customer Service Department or an authorized service center.
Distributor of Teledyne LeCroy: Excellent Integrated System Limited Datasheet of CP015-CF01 - HIGH SPEED CURRENT SHUNT CP015 Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com Operator’s Manual Safety Instructions This section contains instructions that must be observed to keep this oscilloscope accessory operating in a correct and safe condition. You are required to follow generally accepted safety procedures in addition to the precautions specified in this section.
Distributor of Teledyne LeCroy: Excellent Integrated System Limited Datasheet of CP015-CF01 - HIGH SPEED CURRENT SHUNT CP015 Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com ADP015 Current Probe Observe all terminal ratings. To avoid electric shock or fire, do not use the probe above the current & voltage limits shown on the probe as well as all accessories.
Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com Operator’s Manual Specifications The following specifications are valid for model AP015 current probes after the probe has reached operating temperature, which is 20 minutes with power applied in a environment with stable ambient temperature. The probe must be...
< 0.06 Ω at 5 MHz Insertion Impedance: Performance Verification This procedure can be used to verify the warranted characteristics of the AP015 Current Probe. The recommended calibration interval for the model AP015 Current Probe is one year. The complete performance verification procedure should be performed as the first step of annual calibration.
Page 10
Distributor of Teledyne LeCroy: Excellent Integrated System Limited Datasheet of CP015-CF01 - HIGH SPEED CURRENT SHUNT CP015 Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com Operator’s Manual Table 1. List of Required Equipment Description Minimum Requirements Test Equipment Examples Wide Band oscilloscope Minimum 200 MHz bandwidth...
Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com ADP015 Current Probe Preliminary Procedure 1. Connect the AP015 to the channel 1 input of the oscilloscope, and completely close the probe slider. 2. Turn the oscilloscope on and allow at least 30 minutes warm-up time for the AP015 and test equipment before performing the Verification Procedure.
Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com Operator’s Manual Performance Verification Procedure The warranted characteristics of the AP015 Current Probe are valid at any temperature within the Environmental Characteristics listed in the Specifications. However, some of the other test equipment used to verify the performance may have environmental limitations required to meet the accuracy needed for the procedure.
Page 13
Figure 1, DC Accuracy Test Set Up 5. With the AP015 removed from any signal and the slider returned to the LOCKED position, degauss the probe by pressing the DEGAUSS button (located in the Coupling menu) twice.
Page 14
Datasheet of CP015-CF01 - HIGH SPEED CURRENT SHUNT CP015 Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com Operator’s Manual 6. Open the AP015 slider and position the probe input around the 50 Turn loop. Close and LOCK the slider. 7. Set the oscilloscope channel vertical scale to 20 A/div.
Apply a suitable calibration label to the AP015 housing as required. Adjustment Procedure This procedure can be used to adjust the AP015 Current Probe in order to meet the warranted gain specification. The other parameters verified in the Performance Verification procedure do not have adjustments associated with them.
ProBus interface housing. Gently pull on the probe cable to slide the circuit board assembly from the metal housing. 2. Connect the AP015 (without the compensation box cover ) to the oscilloscope using the setup for the DC Accuracy check in the Performance Verification Procedure.
Page 17
LOCKED position, degauss the probe by pressing the DEGAUSS button (located on the coupling menu) twice. 2. Connect the AP015 to the 50 Turn loop, and set the oscilloscope vertical scale to 20 A/div. 3. With the power supply set to 0 V, press the 'Null' button of the multimeter measuring the probe voltage to subtract the probe's offset voltage from the measurement.
Distributor of Teledyne LeCroy: Excellent Integrated System Limited Datasheet of CP015-CF01 - HIGH SPEED CURRENT SHUNT CP015 Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com Operator’s Manual Certifications EMC Compliance EC D - EMC ECLARATION OF ONFORMITY The probe meets intent of EC Directive 2004/108/EC for Electromagnetic Compatibility.
The probe is subject to disposal and recycling regulations that vary by country and region. Many countries prohibit the disposal of waste electronic equipment in standard waste receptacles. For more information about proper disposal and recycling of your Teledyne LeCroy product, please visit teledynelecroy.com/recycle. ESTRICTION OF...
Distributor of Teledyne LeCroy: Excellent Integrated System Limited Datasheet of CP015-CF01 - HIGH SPEED CURRENT SHUNT CP015 Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com Operator’s Manual Contact Teledyne LeCroy Teledyne LeCroy Service Centers United States and Canada - United States - Protocol Solutions Group...
Appendix A: Performance Verification Test Record Permission is granted to photocopy this form and use it to record the results of measurements made during the performance verification of the AP015 Current Probe. File the completed record as required by applicable internal quality procedures.
Distributor of Teledyne LeCroy: Excellent Integrated System Limited Datasheet of CP015-CF01 - HIGH SPEED CURRENT SHUNT CP015 Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com Operator’s Manual AP015 Test Record Serial Number: Asset or Tracking Number: Date: Technician: Equipment Used CALIBRATION MODEL SERIAL NUMBER...
Page 23
Distributor of Teledyne LeCroy: Excellent Integrated System Limited Datasheet of CP015-CF01 - HIGH SPEED CURRENT SHUNT CP015 Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com ADP015 Current Probe Results Step Description Intermediate Data Test Result Bandwidth: Probe Bandwidth (> 50 MHz) ___________MHz DC Accuracy:...
Page 24
Distributor of Teledyne LeCroy: Excellent Integrated System Limited Datasheet of CP015-CF01 - HIGH SPEED CURRENT SHUNT CP015 Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com...
Page 25
Distributor of Teledyne LeCroy: Excellent Integrated System Limited Datasheet of CP015-CF01 - HIGH SPEED CURRENT SHUNT CP015 Contact us: sales@integrated-circuit.com Website: www.integrated-circuit.com...
Need help?
Do you have a question about the AP015 and is the answer not in the manual?
Questions and answers