The yellow, blue, green and red hoses should
be positioned in two layers. The bottom layer
should be made up of the green (left) and
yellow (right) hoses. The top layer of the red
(left) and blue (right). The black hose is
routed to the left between the layers when
half of the hose protection has been wound
on.
Tightening torque couplings 45 Nm
(4.5 kpm).
1.
Connect all the hoses' rear couplings so
that the hoses are positioned correctly
lengthwise in the bundle. Green is
connected to the rear connection on the
hydrostatic motor. Red, blue and yellow
are connected to the front of the pump.
2.
Collect the hoses in two layers: green/
yellow and red/blue in their pipe holders.
3.
Guide the end of the hose protection
between the two layers and wind the
protection 4 turns.
4.
Insert the black hose on the left-hand
side of the bundle.
5.
Wind the hose protection around all 5
hoses a further 4 turns.
6.
Connect the front ends of the hoses to
the pipes, see figure "Hose marking" on
page 105.
106
English-
HYDRAULIC SYSTEM
View from the left
View from the right
View from the front