Level 1 – Password protected level used for configuration of user-settable parameters;
interactive single-line data output per command
8.5

COMMAND SUMMARY

The RETURN or ENTER key is the last character of the command string. If either key is pressed
without a command string the result is an invalid command and will resume continuous display if in
Level 0 or return to prompt if in Level 1.
Keystroke
ESC
sp(spacebar)
A
C
=<password>
90000012 R8
HY-ALERTA™ 1600, Intrinsically Safe Area Hydrogen Monitor
Level 0 Commands
Stops continuous display to enter a password or command. If in level zero, the
continuous display will resume after executing one command.
Pressing the Space key while the serial output is active will display a label line
showing the heading for each column of data.
Average readings.
Clear peak hydrogen value.
Enter the password to change security level. A null or invalid password returns to
the default security level.
Level 0 password = "0"
Level 1 password = "h2scan"