Test 2200 - IBM Personal Computer Cluster Adapter
(continued)
11. You have stations that are not indicated on any status screen presentation, or by a cluster-
access error message.
•
Perform the system diagnostic tests on a station that is not indicated on any status screen
presentation or that has a cluster-access error.
•
If
the diagnostic tests fail, have the system unit serviced.
•
If
the diagnostic tests pass, continue performing the diagnostic tests until you test all of
the stations that did not appear on any cluster-status screen presentation or that had a
cluster-access error.
•
If
the Cluster Adapters pass the diagnostic tests and the stations did not appear on the
cluster-status screen presentations, contact your installation manager. The problem
may be with the coaxial cable or a terminating plug.
Note:
If
you have more than one cluster adapter installed in your system, go back to
5-2200-1 and continue testing until all cluster adapters have been tested.
Chapter 5.
Problem Determination Procedures
5-2200-11