Whirlpool CHCH8AE Installation Instructions Manual
Whirlpool CHCH8AE Installation Instructions Manual

Whirlpool CHCH8AE Installation Instructions Manual

Whirlpool commercial ice maker installation instructions

Advertisement

Quick Links

IMPORTANT
INSTALLATION INSTRUCTIONS
for
MALFUNCTION
LIGHT.
"ON-OFF-CLEAN"
SWITCH
BEHIND
NAMEPLATE
Whirlpoo
CORPORATII
Electrical
Supply
115208/230
V. 3-Wire
60
Hz-l
Ph.
NOTICE:
ICE STORAGE
BIN SUPPLIED
SEPARATELY.
It is essential
that
a suitable
ice storage
bin
of durable
construction
be used with
the ice
cube maker
and that the method
of mounting
be dimensionally
compatible.
NOTICE:
The interior
walls of the ice maker
should
at least
line
up with
the
interior
walls
of the storage
bin. There should
not be
any interior
ledge projection
of the bin walls.
An overhang
of the ice maker
exterior
walls
is permissible.
COMMERCIAL ICE MAKER
MODELS
CHCH8AE CHCH8WE CHCH8AS CHCH8WS
Benton
Harbor,
Mlchlgan.
Auromatlc
Washers,
Clothes
Dryers,
Freezers,
Refrlgeralor-Freezers,
Ice Makers.
Dlshwasherr,
Budt-ln
Ovens
and Surface
Umts,
Ranges,
Mwowave
Ovens,
Compactors,
Room
AN
Condltmners,
Llehumldifwrs.
Central
Heatmg
and
Air Conditmnmg
Systems.
Part No. 756832
2-w

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool CHCH8AE

  • Page 1 INSTALLATION INSTRUCTIONS MALFUNCTION LIGHT. “ON-OFF-CLEAN” SWITCH BEHIND NAMEPLATE COMMERCIAL ICE MAKER CHCH8AE CHCH8WE CHCH8AS CHCH8WS IMPORTANT Whirlpoo CORPORATII MODELS Benton Harbor, Mlchlgan. Auromatlc Washers, Clothes Freezers, Refrlgeralor-Freezers, Ice Makers. Dlshwasherr, Ovens and Surface Umts, Ranges, Mwowave Ovens, Compactors, Room Condltmners, Llehumldifwrs.
  • Page 2: General Information

    1 BEST \ RANGE 70’ wall air cir- on top 1000 the room to main- than available a Whirlpool bin or will ice maker and the 1. Using 2” x 4” blocks lay cabinet CAUTION: ice maker head 2. Leaving...
  • Page 3: For The Electrician

    FOR THE ELECTRICIAN CONFORM TO ALL APPLICABLE personal responslbrlrty cuslomer to contact a qualIfted installer electrtcal rnstallatron IS adequate and IS In conformance with National ElectrIcat Code ordrnances A separate circuit must be used NOTE: time delay fuses. REMOVE TOP SHROUD 1.
  • Page 4: For The Plumber

    FOR THE PLUMBER CONFORM TO ALL APPLICABLE CODES INSTALL DRAINS %” O.D. TUBE SUPPLIED FROM ICE MAKER WITH WHIRLPOOL BIN DRAIN NOTE: Ye” dra. siphon break hole verhcal leg of white vtnyl tubing. The storage bin drains by gravity and, therefore,...
  • Page 5 INSTALL LOOSE PARTS ICE THICKNESS WATER LEVEL FLOAT ADJUSTMENT \’ The following loose parts packed InsIde to be field Installed 1. Water Pump Pan. Hold so the gradua!ly area IS at left Place the left 11p edge evaporator on the top of the entering lower cutter...
  • Page 6: Check Operation

    START-UP AND CHECK-OFF Start the unrt by opening water valve service switch to “ON ” NOTE: In “CLEAN” positron, only ooerates 3. Check water level In pump pan. water level should be 11/4” deep. 4. Check for even water flow over must be level for proper operation.
  • Page 7: Schematic Wiring Diagram

    SCHEMATIC WIRING DIAGRAM DANGER ELECTRICAL SHOCK HAZARD DISCONNECT POWER BEFORE SERVICING THIS UNIT MUST BE WIRED AND PERMANENTLY GROUNDED in accordance with the National Electrical Code and applicable codes and ordinances A separate LIGHT ON -OFF CLEAN SWITCU SLAB .OtvlPL ZELAY RELAY UOT GAS...
  • Page 8 CONNECTION DIAGRAM -COMPL. RELAY II I START RELAY CONTROL TRANSFORL TR&N’)FORMER UOLDING RELAY...